Automatic Cleaved Open Cup Test
Features
- Temperature Range: 79 to 400 ℃.
- Test Method : ISO 2592 , ASTM D 92 , IP 36 , IS 1448 ( P-69).
- Ignition Source : Gas Flame with two Pilot electric Coil.
- Temperature Sensor : PT-100 in stainless steel sheath.
- Flash/Fire Detector: Ionization principle based flash-detector sensor.
- Controller: HMI Touchscreen with colour display and Inbuilt storage of approx. 300 sample with audio visual alarm to check the machine. 3-wire RTD temperature sensor, free potential flame detector sensor as i/p. with automatic barometric reading correction.
- All necessary interlock for self-detection of fault.
- Flame-Sampling Arrangement: 10 Rpm, D.C. 12 v or 24V DC, gear motor, vertical movement reciprocating to & fro motion.
- Heater: 800 W, 230 v.
- 1Electrical ignition for pilot flame-sampling. Ignition transformer having continuous o/p of 10.6 kV. D.C. from 230 v A.C. i/p.
- Equipment Overall Size (LxWxH): 280mm (W) X 530mm ( D ) X 415 mm ( H )
- Equipment Gross Weight: 22 Kg.
- Equipment supply will be 230 V Ac , 50 Hz with 15 amp capacity.