Highest quality standards are achieved through the implementations of latest technology, decades of experience and everlasting moral values , which have helped us to retain our customers as well as multiply them.
Microminus rectifiers are designed for 415 volt,3-Phase,50Hz,a.c.input Supply With D.C.out put Variable With Dimmerstate from 0 to maximum rating of o/p voltage/Current. The three Phase oil Cooled rectifiers are preferred for more Then 250 ampere capacity. The unit Will be Provided With double wound Transformer, Dimmerstate, Diode assembly, shunt, Analog/Digital Meters of the standard grade.
The unit will be fully immersed in to oil tank filled with transformer oil. Castor wheel is provided to move the entire unit easily.
The latest developed single/three phase rectifiers are designed to provide better quality of electroplating as saved electrical Power to the great extent.
The unit is totally indigenously developed with our highly qualified team & well advanced instrumentation facility. The out put voltage can be available up to 100 volt as well as out put current can be available up to 15,000 ampere capacity.
Advantages
Hullcell Rectifiers :
CVCC Rectifier are available in the range up to 100ampere. Constant current or voltage can be set with the knob on the front. Ripple factor less than 1% will provide accurate control of current. Digital volt/ampere meters, digital timers will be provided on the front.
Most Preferable for GOLD, SILVER PLATING, RHODIUM PLATING. NICKLE PLATING, can be used for HULLCELL TEST.
Standard Available Ranges :
Single phase rectifiers are available up to 250 Ampere capacity in the various voltage ranges. Dimmerstate on the front used to set the o/p voltage. The Unit Will Comprises of Digital Voltmeters, ammeters, Timers, Ampere hour meter. Above 250 Ampere 3 Phase Rectifiers are Preferable.
Standard Ranges Available :
( With Timer/Without Timer ) :
25 Ampere – 8 Volt / 12 Volt / 16 Volt / 24 Volt
50 Ampere – 8 Volt / 12 Volt / 16 Volt / 24Volt
100 Ampere – 8 Volt / 12 Volt / 16 Volt / 24 Volt
50 Ampere – 8 Volt / 12 Volt / 16 Volt / 24 Volt
For the Selective Electroplating of Delicate Areas like Rhodium, Gold and Silver.
Rectifier :
Voltage-Stabilized and double insulated for 240v/ ~50 / 60Hz
Max output current :
20 volt, 1.5 A
|
|
|
|
|
|
|
|
|
|
|
|
|
Latest developed LED unit comprises of digital voltmeter, Ampere meter, Timer, Ampere hour meter.
As the LED Display with Backlight, Least Chance of Digits.
As it is micro controller unit, indicates the accurate reading of the measurement.
Robust push button will improve the reliability of the unit.
Timer or Ampere Hour Meer Selection, Ampere Hour/ Minute/ Second Selection on the Back of The Instrument.
The unit available in the size of 196mm*96mm*160mm covers wide range of ampere hour / minute / second for the shunt value up to 20000 ampere.
Versatility:
The same unit can be used for any rectifier setting, the DIP switches on backside of the unit.
AMPERE HOUR TOTALISER: MME-9601
It is Ampere Hour/minute/ second Totaliser to totalize the total counts in stipulated time with reset facility provided on the front.
The instrument is useful to control the temperature of plating bath by making on/off the heater. On the display will indicate the bath temperature. On pressing the SET button & moving the Adjust, cut off value can be Set. Pt 100 Sensor of Titanim Metal will be supplied to provide better accuracy & to prevent corrosion to the Sensors.
This instrument is very useful where heaters are to be started in the early morning. By Setting the heater ON time on the front. (Let ON time -6a.m., OFF time-7p.m.), the heaters will be Started at 6a.m.morning, it will control the Temperatute of the bath for the whole day, At 7p.m. evening it will make off the heaters. Again next day 6a.ma Heatres Will be started & so on. Weekly off can also be set in the instrument.
|
|
We manufacture various types of ultrasonic cleaners for laboratory applications such as degassing, glassware cleaning etc. Ultrasonic Laboratory cleaner helps in removing grease, dust and other contaminants from the surfaces and cavities of small objects, parts and samples such a corvettes, lenses, Stainless steel instruments, glassware, metals and more.
Ultrasonic Cleaners Helps too much to remove dust, oil, grease etc. from the object where cleaning manually With Hand / Grinding / Buffing is not Possible by Generating High Frequencies beyond audible range.
Available in Various Capacities.
Chemical Dosing System is developed to add chemical/Brightner as the plating is done. The basic is Ampere Hour Count. As the plating is done & set Ampere Hour is passed,Set ml of chemical will dose in the plating tank.
As Ampere Hour & ml of addition is both programmable,Chemical can be dose in a minimum interval to maintain the regular addition.
Brightener addition:
when brightner is added, at that time,material plated will be too bright & as the brightner is consumed material plated will become dull later on.With this system,The regular addition of brightner will maintain the brightness quality for the whole day of plating time.
Digital pH Meters Developed by microminus is table top model to be used in laboratory for measurement of pH of chemical from 0 to 14 PH. The unit is developed keeping in calculation all the parameters of temperature, asymmetry of glass probe & slope control to Caliberate the instrument perfectly.
* To embrace new technologies and methods. * To give unsurpassed products and services to the clients. * To constantly look for improvement and changes.