Glass Tube Rotameter

  /> </div>
<div class=

Glass Tube Rotameter: It is basically a variable area flow meter. The differential pressure across the annulus area is constant and the flow rate is measured as a function of the annulus area created by ‘Float’ position.

Glass Tube Rotameter With Transmitter

  /> </div>
<div class=

Glass Tube Rotameter with Transmitter: It is basically a variable area flow meter. 2-Wire Transmitter is provided for conventional Glass Tube Rotameter. The O/P is 4-20mA which is proportional to flow

Metal Tube Rotameter

  /> </div>
<div class=

Metal Tube Rotameter: It is basically a variable area flow meter. The differential pressure across the annulus area is constant and the flow rate is measured as a function of the annulus area....

Metal Tube Rotameter With Transmiter

  /> </div>
<div class=

Metal Tube Rotameter with Transmitter: It is basically a variable area flow meter. 4-Wire Transmitter based on ‘Hall Effect’ is provided for conventional Metal Tube Rotameter. The O/P is 4-20mA which is proportional to flow rate.

By Pass Rotameter

  /> </div>
<div class=

By-Pass Rotameter: It is an inference type flow meter. Because of the differential pressure, this is generated due to Orifice Plate; a branch of flow flows through the by-pass line. By measuring the flow from by-pass line we can estimate the flow through the Main Line.

Acrylic Rotameter

  /> </div>
<div class=

Acrylic Rotameter: It is basically a variable area flow meter. The differential pressure across the annulus area is constant and the flow rate is measured as a function of the annulus area created by ‘Float’ position. It is made from a Acrylic Block.

Low Flow Rotameter

  /> </div>
<div class=

Low Flow Rotameter: It is basically a variable area flow meter. Used for low flow ranges

Low Flow Rotameter With Dp Regulator

  /> </div>
<div class=

Low Flow Rotameter with DP Regulator: It is basically a variable area flow meter. Used for Nitrogen Purging in a tank. The flow remains constant irrespective of the downstream pressure.

G.T.R With Flow Switch

  /> </div>
<div class=

Tansa Switch can be also used
wherever Bi-stable conditions
are to be sensed.

Square Edge Co Centric Orifice Plate

  /> </div>
<div class=

Square Edge Co-centric Orifice Plate: These are most commonly used for flow measurement. This has special feature simple structure, high accuracy and easy installation. These Orifice Plates are recommended where Reynolds number range from 10000 to 10^7.

Eccentric

  /> </div>
<div class=

Eccentric: These are used for liquid containing solid particles which are like to sediment or for vapors likely to deposit water condensate, this orifice plates are used with its eccentric bore at the bottom side so that sedimentation of such inclusions are avoided. For Gases and Vapors it may be installed with the eccentric bore at the top side to avoid stay of gas or vapor in its vicinity

Segmental

  /> </div>
<div class=

Segmental: The bore of this type of orifice plates is a semi-circle. It used where solids are entertained in liquid or gas streams

Quadrant Edge

  /> </div>
<div class=

Quadrant Edge: The inlet edge of the bore of this orifice plate is rounded to a quarter circle. This orifice plate is principally used for measuring flow rates of low Reynolds number (Between 2000 to 10000)

Restriction Orifice Plate

  /> </div>
<div class=

Restriction Orifice Plate: These Orifice Plates are used for reducing fluid pressure. These orifice plates are slightly different from standard orifice plates.

Orifice Assembly

  /> </div>
<div class=

Integral Orifice Assembly : This type of assembly is used where the Differential Pressure Transmitter has to be mounted directly on the Orifice Assembly. This eliminates the impulse tubing from Orifice Assembly to DP Transmitter. This type of assembly is used for line size below 2” (50 NB). The transmitter in mounted on the orifice assembly with the help of 3-Way Manifold. The assembly consists of orifice plate with two integral blocks having corner taps. It also consists of a meter run pipe having length of 750mm on the upstream side and 250mm on downstream side.

Full Bore Electromagnetic Flow Meter

  /> </div>
<div class=

• Wide range of sizing DN25 to DN350.


• Higher sizes are also available but Model is Mega-Sroat (Diameter DN400 to DN1600).
• Accuracy ±0.5% of actual flow rate.
• Wide choices of compatible electrodes, liners & Body materials.
• 5000 / 10000 Number of readings can be logged.
• Computer/Printer Interfacing with RS 232 / RS485 port.
• Stored/ Online data can be store in excel format file by using RS232 Monitor Software PC end Most suitable full bore electromagnetic flow meters for water and waste water treatment plants.

Full Bore Electromagnetic Flow Meter Wafer Type

  /> </div>
<div class=

• Economically Priced, Wafer Style Meter.
• Available from DN50 to DN200.
• Small in size and light in weight compared to other meters in its class.
• Typical accuracy; better than 0.5% of reading.
• Suitable for Waste water; Sewage Water; Effluent water.

Full Bore Electromagnetic Flow Meter Sanitary Grade

  /> </div>
<div class=

• Full stainless steel construction with PTFE Liner.


• Suitable for any type of Dairy Fluids like milk, cream etc. Also suitable for Pharma liquids, juices of various fruits.
• Available in two types of end connections; SMS or DIN Union and Tri-Clover clamps.
• Sizes available from DN25 to DN100. Lower Sizes on Request.
• Highly Accurate and Linear.
• Highly Accurate and Linear.
• Isolated Analog and digital Output.

Transparent Level Indicator

  /> </div>
<div class=

It gives an accurate reading of liquid level, clear glass is mounted on the front and back of the gauge. The permits the observer to see not only the level of the liquid, but also its characteristics such as color or the interface between two im miscible liquids in the same system.

Reflex Level Indicators

  /> </div>
<div class=

It gives an accurate reading of liquid level; colorless liquid can be seen using the principles of light reflection and reflection through the special prism glass. Light striking the area of glass covered by the liquid is allowed to pass to the interior prof the gauge- this area appears black. Light striking the area of glass above the liquid is reflected black silver. The distinct line that separates the black and silver areas shows .

Magnetic Level Indicator

  /> </div>
<div class=

 

[Magnetic Bi-Color Level Indicator]

Connection : Flange; ASA #150 RF.
Range : 300 mm to 6000 mm.
Pressure Rating : 25 KG/CM2.
Temp. Rating : 150 Deg C.
MOC : SS 304 / SS 316 / PP.

It is used to measure the level of fluids. Fabricated using superior quality basic material by employing advanced machinery and sophisticated tools, these products compiled to the defined parameters of the industry in an efficient manner. These magnetic level indicators are mainly used in the hazardous pressurized vessels. Therefore, customers can avail these offered products from us in multifarious sizes and specifications as per their requirement.

Float And Board Level Indicators

  /> </div>
<div class=

It is attached to a multi strand wire rope, which passes through 2 nos. friction less specially designed pulleys. The Pulleys in turn are connected to a pointer, which moves on a graduated scale by the side of the tank.

Tubular Level Indicator

  /> </div>
<div class=

We are one of the leading manufacturers & exporters of Tubular Level Indicator. These are designed by our team of experts using latest technology in accordance with the market requirement. Our Tubular Level Indicators are used in various industries due to their vast features & technical specifications. Our products are highly appreciated by our esteemed clients due to their quality material.

Top Mounted Level Indicator

  /> </div>
<div class=

• Specially designed for underground Tanks


Connection : Flange; ASA #150 RF
Range : Upto 3 Mtrs.
Pressure Rating : 20 KG/CM2
Temp. Rating : 150 Deg C

Double Window Sight Flow Indicators

  /> </div>
<div class=

[Sight Flow Indicator]

TANSA make double window sight flow indictors are engineered to perfection having different models suiting different application and mounting orientation with robust body superbly welded and cover plate bolted with over size toughened glass for clear and visualization of liquids in turn enables wellness of line avoiding harmful choking. Various different models are available as per required application and in different material of construction, M.S, 304 S.S, 316 S.S.

Full View Sight Flow Indicators

  /> </div>
<div class=

TANSA make full view sight flow indicators are demanded for its clear flow visualization. It is used for visualization of flow in line having DM water, acids and chemicals having less of particulates in it. The use of toughened borosilicate glass has made our full view sight flow indictors robust and steardy in long run. TANSA make full view sight flow indicators are recommended for vertical flow as well as horizontal flow. We manufacture sight glass flow indicator in varied material of construction suiting the service the best taking into consideration pressure and temperature details of our clients.

U Tube Manometer

  /> </div>
<div class=

INTRODUCTION :

TANSA make U - Tube Manometer is the basic and mostly used style of manometer. The U - Tube manometer is a versatile, economical instrument for the measurement of pressure, vacuums or differential pressures. Pressure measurements are accomplished by balancing a vertical head of indicating fluid with the pressure to be measured. As there is no cams, gears or levers to operate in the manometer, the readings obtained are always accurate.

PRINCIPLE:

The U Tube Manometer, have “U” shaped tube, half filled with liquid (Water / Mercury / SP Gr. 0.81). When both the tubes are open, the liquid is at the same height in each leg (Tube / Limbs). When positive pressure is applied to one leg the which is the sum of the reading above and below zero, tells you the pressure. When vacuum is applied to one leg, the liquid rises in that leg and falls in the other. The difference in the height indicates the amount of vacuum. The U Tube Manometer, consisting of two Glass Limbs. Stainless Steel / Brass Connecting fittings mounted on a metallic frame, provided with White Acrylic Scale with zero at the center. The U Tube Liquid Column Manometer we provide is used to determine Velocity and Static Pressure, Leakage, Fan Efficiency and Gas Pressure. The Manometer will be protected with transparent acrylic front cover fix with Aluminum frame and external zero adjustment Knob / Drain Plug / Fill Plug will Be Provided

Single Limb Manometer

  /> </div>
<div class=

TANSA make Single Limb Well Type Manometer is used for direct reading for the
precision measurement of pressure, vacuum, differential pressure, flow and liquid level measurement
device ideal for various process applications. These Manometers are general purpose, direct reading
and relatively simple instruments. The well type single limb manometer is accurate & reliable as well as
highly versatile for many applications. All scales are graduated to correct for the drop in the well level.

Basket Type Strainer Simplex Strainer

  /> </div>
<div class=

Company engaged in designing and manufacturing various size of Bucket strainer with different design customize to suit as per customers requirement.

Basket Type Strainer Duplex Strainer

  /> </div>
<div class=

C.S with Rubber line or SS 304, SS 306, Magnetic, bucket strainer is advisable where liquid has to be separated from Iron particle. These magnetic are of 10000 gauge which can be installing in bucket according to size of bucket.

Synchronizing Panel

  /> </div>
<div class=

Synchronizing Panel works between two or more different power sources like DG sets to manage power supply. Synchronization helps in making different DG sets behave as a virtual single unit and eliminates subdivision of total load. It helps in transferring load from one unit to another as during service period, so that the unit requiring service can be easily shut off. In this way the critical load need not be interrupted and there is no production loss. During low load we can run any single unit, and synchronize more units as the load increases. This can be manual or automatic. 

LT Panel and HT Panel :
LT Panel is an electrical distribution board that receives power from generator or transformer and distributes the same to various electronic devices and distribution boards. Such panels are used in industries both for internal and external use and, therefore, they are quite rugged to withstand different climatic conditions. Our LT panels are designed to work with low electricity consumption that makes them cost effective

HT Panel is like LT Panel except that it is used for high tension cables.

A.P.F.C (Automatic Power Factor Control) Panels

  /> </div>
<div class=

[APFC (Automatic Power Factor Control) Panels]

These panels are used in commercial buildings and industries where there is fluctuation in voltage and power supply. The electrical load required by a unit depends upon the type of machineries, cooling plants and other devices installed. There is always a possibility of damage of these equipments if power fluctuates. In case of fixed loads they can be safeguarded using capacitors, but in case of varied loads, a mechanism to switch in and switch out the capacitors is required which is basically handled using APFC panels.

PCC (Power Control Center) Panels:
Its basic function is to control power supply to various units and equipments as per their load requirement so that they can work in harmony.

Our Vision

* To embrace new technologies and methods. * To give unsurpassed products and services to the clients. * To constantly look for improvement and changes.

Site Designed & Maintained by Aman Infotech
A. P. F. C (Automatic Power Factor Control) Panels, Acrylic Rotameter, Averaging Pitot Tube Annubar, Basket Type Strainer Duplex Strainer, Basket Type Strainer Simplex Strainer, Bucket Type Strainers, By Pass Rota Meters, By Pass Rotameter, By Pass Type Rotameter, Carrier Ring, Condensing Pot, Double Window Sight Flow Indicators, Eccentric, Elecrtomagnetic Flow Meter, Electromagnetic Flow Meter, Five Way Manifolds, Flange Tape Type Rota Meters, Float And Board Level Indicators, Flow Indicator And Totaliser, Flow Measuring Instruments, Flow Nozzle, Full Bore Electromagnetic Flow Meter, Full Bore Electromagnetic Flow Meter Sanitary Grade, Full Bore Electromagnetic Flow Meter Wafer Type, Full View Sight Flow Indicators, G. T. R With Flow Switch, Glass Tube Rota Meters, Glass Tube Rotameter, Glass Tube Rotameter With Transmitter, Glass Tube Type Purge Rotameter, Glass Tube Type Rotameter, Home, Integral Orifice Assembly, Isolation Valves, Level Measurement, Loop Power Indicator, Low Flow Rotameter, Low Flow Rotameter With Dp Regulator, Magnetic Implex (Duplex Strainer), Magnetic Level Indicator, Metal Tube Rota Meters, Metal Tube Rotameter, Metal Tube Rotameter With Switching Alarm, Metal Tube Rotameter With Transmiter, Metal Tube Rotameter With Trasnmitter, Multi Stage Restriction Orifice Plate, Orifice Assembly, Orifice Flange Assembly, Orifice Plate, Paddle Type Switch, Plunger Type Switch, Positive Displacement Flow Meter, Pressure Measurement, Process Indicator And And Totaliser, Purge Rotameter With Dp Regulator, Quadrant Edge, Reflex Level Indicators, Restriction Orifice Plate, Rota Meters, Rotameter With High Flow (Latching) Switch, Rotameter With Low Flow (Latching) Switch, Segmental, Single Limb Manometer, Square Edge Co Centric Orifice Plate, Strainers, Synchronizing Panel, Three Way Manifolds, Top Mounted Level Indicator, Transparent Level Indicator, Tubular Level Indicator, Turbine Flow Meter, Two Way Manifolds, U Tube Manometer, Ultrasonic Flow Meter, V Cone, Ventury Tube, Vortex Flow Meter