Highest quality standards are achieved through the implementations of latest technology, decades of experience and everlasting moral values , which have helped us to retain our customers as well as multiply them.
Application: Power Distribution for Industrial, commercial, institutional and residential purposes.
Types and Sizes: Up to 4 core ranging from 4 sq. mm to 1200 sq. mm
Conductor: Aluminium – Solid, Stranded (Sector/Circular) or Copper – Solid, Stranded (Sector/Circular) or Flexible
Insulation: PVC – Type A, Type C, Polyetheylene, XLPE, ZHFR, LSZH
Inner Sheath: PVC – ST1, HR, FR, FRLS, LSZH
Armour: Galvanized Steel or Aluminium Wire / Strip / Tape
Outer Sheath: PVC – ST1, HR, FR, FRLS, LSZH, XLPO
Specification: IS: 1554 (Pt-1 & 2), IS: 7098 (Pt-1 & 2) IEC: 60502-1, BS: 5467, BS: 6396
Application: Suitable for connections for Control Circuits, Communication Systems, Electrical Panels, Machine Tools, etc. Also used for lighting at lower loads.
Types and Sizes: Upto 61 cores from 1.0 sq. mm to 2.5 sq. mm.
Conductor: Copper – Solid, Stranded (Circular) or Flexible – Bare or Tinned
Insulation: PVC – Type A, Type C, Polyetheylene, XLPE
Inner Sheath: PVC – ST1, HR, FR, FRLS, LSZH
Armour: Galvanized Steel Wire / Strip / Tape
Outer Sheath: PVC – ST1, HR, FR, FRLS, LSZH
Specification: IS: 1554 (Pt-I), IS: 7098 (Pt-I), IEC: 60502-1, BS: 5467, BS: 6346
Application: Widely used in measurement, communication and data acquisition systems. Also used in microprocessor based / computerised instrumentation system. Designed to transmit without interference.
Types and Sizes: Upto 50 Pairs, Triads from 0.5 sq.mm to 1.5 sq.mm
Conductor: Copper – Solid, Stranded (Circular) or Flexible – Bare or Tinned
Insulation: PVC – Type A, Type C, Polyetheylene, XLPE
Shielding: Aluminium – Mylar Braiding
Inner Sheath: PVC – ST1, HR, FR, FRLS, LSZH
Armour: Galvanized Steel Wire / Strip / Tape / Braid
Outer Sheath: PVC – ST1, HR, FR, FRLS, LSZH
Specification: IS:1554 (Pt-1), BS: 5308 (Pt-1 & 2), IEC: 189 (Pt 1 & 2), VDE: 0815 & 0816, BS EN: 50288
Application: Used in locations where high resistance to heat, oil and fire (HOFR) are required. Commonly used in lifts, cranes, pumps and other heavy duty equipment.
Types and Sizes: Single & multi core from 0.5 sq.mm to 630 sq. mm
Conductor: Flexible Tinned Copper Conductor
Insulation: EPR, CSP, PCP, Silicone Rubber
Inner Sheath: EPR, CSP, PCP, Silicon Rubber
Armour: Copper Wire / Stainless Steel Braiding
Outer Sheath: EPR, CSP, PCP, Silicone Rubber
Specification: IS: 9968 (Pt-1 & 2), BS: 6500, BS: 7919, BS EN: 60332, IEC: 60502
POWER CABLES
CONTROL CABLES
INSTRUMENTATION CABLES
Rubber Cables
SOLAR CABLES
HIGH TEMPERATURE CABLES
CONCENTRIC CABLES
FIRE SURVIVAL CABLES
THERMOCOUPLE
WIND CABLES
RAILWAY SIGNALLING CABLES
OVERHEAD CONDUCTORS
AERIAL BUNCHED CABLES
HOUSE CABLES
FLAT & SUBMERSIBLE CABLE
INDOOR TELEPHONE CABLES
FLEXIBLE MULTI CORE CABLES
FOUNDATION FIELDBUS PROFIBUS CABLES
COAXIAL CABLES
CRD AND TRAILING CABLES
Application: Used for interconnections between solar panels and other electrical components. These are designed to be UV resistant and weather resistant
Types and Sizes: Typically Single or Double core from 2.5 sq.mm to 50 sq. mm
Conductor: Stranded / Flexible Tinned Copper Conductor
Insulation: TPE, XLPO, Ultravoilet – Resistant PVC
Separator: Paper Tape
Outer Sheath: Ultravoilet – Resistant PVC
Specifications: UL Type PV-UL 4703, TUV 2 pfg 1169/08.2007
Application: Used for high temperature applications in Steel, Chemical and Metallurgical industry, aircraft & aerospace vehicle wiring, nuclear power plants, oil exploration & oil rigs, military & defence equipments, auto wiring etc.
Conductor: Bare / Tinned copper (up to 120° C), Silver plated copper (up to 200° C), Nickel plated conductor (up to 260° C).
Insulation: Special compounds used for cables to work upto 350° C
Screening: Individual and/ or overall with Aluminium Mylar tape with tinned copper drain wire / or Braided with bare / tinned / nickel plated /silver plated copper wire.
Armouring: Galvanized steel wire / stainless steel wire.
Specification: IS:8130, IEC: 60228, VDE:0295
Application: Indoor, outdoor and underground installation in ducts. Used for better mechanical protection and higher resistance to fire and toxic fumes
Conductor: Solid / Stranded Bare Copper / Aluminium Conductor
Insulation: PVC- Type A, XLPE, FR, LSZH
Armour: Concentric Copper / Aluminium Conductor / Copper / Aluminium Tape
Outer Sheath: FR, FRLS, LSZH, ZHFR
Specification: BS: 7870, DKS: 1022, Customer Specifications
Application: Designed to maintain circuit integrity during fire. Typically used in fire alarm systems, emergency lighting, critical circuits and other safety equipment.
Types and Sizes: Single Core 16 to 1200 sq. mm Multicore 16 to 400 sq. mm
Conductor: Bare / Tinned Copper, Aluminium – Solid, Stranded or Flexible
Fire Barrier: Layers of Glass Mica Tape
Insulation: Heat Resistant PVC, XLPE, Silicon Rubber with Additional taping or screening if required
Inner Sheath: FR PVC, FRLS PVC, ZHFR, LSZH
Armouring: Galavanised Steel Wire / Strip
Outer Sheath: FR PVC, FRLS PVC, ZHFR
Specification: BS: 7846 or equivalent BS: 6387 Category CWZ, IEC: 6033, Customer Specifications
Application: Desigined for interconnection between Thermocouple probes and Reference units
Construction Details: Chromal Alumel/Iron/Copper Constantan Alloy -Solid / Stranded
Types and Sizes: KX, VX, EX, SX- Typically from 16-20 AWG
Insulation: PVC-Type A, HR, Polyetheylene, XLPE
Shielding: Aluminium – Mylar / Copper Braiding
Inner Sheath: PVC – ST1, HR, FR, FRLS
Armouring: Galavanised Steel Wire / Strip
Outer Sheath: PVC – ST1, HR, FR, FRLS
Specification: ANSI: MC 96.1, IS: 8784, BS: 4937, IEC: 584
Power Cable: For transmitting power from the generator mounted in the nacelle of the wind tower to base station. Flexible cables made of special elastomeric compounds to meet torsional stresses exerted to rotation of the nacelle in relation to wind direction.
Conductor: Flexible class-5 tinned or bare copper conductors, made to IEC-60228/IS-8130
Range (single cover): 10 Sq mm to 300 Sq mm
Insulation: EPR
Sheath: Special elastomer compound with Oil, Fire, Hydrolysis and Torsion Resistant properties. (Zero halogen sheath available upon request)
Control & Instrumentation Cable: For used in Wind Energy applications such as rotor blade pitch control, Yaw control, Top box, Anemometer feed back, Remote data logging etc.Construction as per Customer’s requirement and conforming to various National/International Standards.
Application: Used in all railway applications including light switching, track changing and communication.
Types and Sizes: Screened / Unscreened upto 61 Cores
Conductor: Solid Circular Conductor
Insulation: PVC with IRS Properties
Inner Sheath: PVC
Armour: Galvanised Wire or Strip / Double Steel Tape
Outer Sheath: PVC with IRS properties
Specifications: Indian Railway Specifications: S-63/2014 with upto date amendments
Application: Transmission & Distribution Overhead Power Lines
Conductor: Stranded Aluminium, Aluminium Alloy
Specification: IS 398, BS EN 50182, IEC 61089, DIN 48201
(1) AAC: All Aluminum Conductor
(2) ACSR: Aluminum Conductor Steel Reinforced
(3) AAAC : All Aluminum Alloy Conductor
(3) ACAR : Aluminum Conductor Alloy Reinforced
(4) ACSR/AW: Aluminum Conductor Steel Reinforced/Aluminium Clad Steel Core
(5) AACSR : All Aluminum Conductor Steel Reinforced
(6) AACSR/AW: All Aluminum Conductor Steel Reinforced/Aluminium Clad Steel Core
(7) Special Conductors: GAP, INVAR, ACCC
Application: Residential, Commercial, Buildings, Multplexes, Institutional & Industrial applications
Size: Two, Three or Four Core from 0.75 to 6 mm.sq.
Conductor: Multi Stranded Plain / Tinned
Insulation: PVC, HR PVC, FR, FRLS, LSZH
Inner Sheath : PVC, HR PVC
Outer Sheath: PVC, HR PVC, FR, FRLS, LSZH
Specification: IS: 694, BS: 6500, Customer Requirements
Application: For Bi-directional communications protocol used for communications amongst field devices and control system. Installed in refining, petrochemicals, power generation, food & beverage, pharmaceuticals and nuclear applications.
Conductor: Bare / Tinned copper (up to 120° C), Silver plated copper (up to 200° C), Nickel plated conductor (up to 260° C).
Range: 22 AWG / 18 AWG / 16 AWG / 14 AWG
Insulation: Polyethylene, XLPE, PFA for temp.>150 Deg. C
Inner Sheath: PVC Type A, HR, FR, FRLS, ZHER, FEP, PFA
Armour: Round Galvanized Steel Wire/Flat Strip/Steel Wire Braid
Outer Sheath: PVC, HR, FR, FRLS, ZHER, FEP, PFA with plain Orange Jacket or with strip for easy identification. Blue Jacket also available for Safe application.
Specification: Foundation Fieldbus FF-844H1, Design based on EN50288-7/ BS: 5308 (Pt-1), IEC 60332, Electrical properties : FF-844H1 and IEC 61158-2
Application: Used for transmission of radio frequency signal and for connections to systems in local area networks (LAN), cable televisions, PlCC Communication etc.
Construction Details: Typically solid copper conductor. Stranded /Flexible
conductor is also available
Types and Sizes: Usually manufactured for Impedance of 50 to 125 Ohms.
Insulation: Polyethylene, Cellular PE, Foam PE
Shielding: Aluminium – Mylar / Copper / Steel Braiding
Outer Sheath: PVC-ST1, HR, FRLS, PE
Specification: Radio Guide and Military MIL-C-17, IS:11967, BS:2316 & Customer Specifications.
Application: Used in conveyor machinery such as transfer cars, boomstackers, side arm chargers, bulk materials conveyors etc.They find application in almost every industry segment like Steel Mills, Cement plants, Docks, Power Plants, Automobile Industries & Refineries and Petrochemicals.
Conductor: Class-5 flexible tinned or bare copper
Insulation: EPR
Screening (if Applicable): Tinned or bare copper wire braid
Inner Sheath: HOFRElastomer
Anti Kink Braid: Fibre braid embedded between inner and outer sheath
Outer Sheath: HOFR-Elastomer
Features: Designed to withstand continuous reeling and unreeling, Sheath materials that have a high degree of flexibility, excellent heat resistance, oil and fire resistant properties.
Specification: Customer Specifications
Application: Typically used in over-head power transmission & distribution and in temporary installations
Conductor: Aluminium Circular Phase Conductors with messenger upto 120 mm.sq.
Messenger: Aluminium Alloy or Galavanized Steel Messenger Conductor.
Insulation: Polyetheylene, XLPE, HDPE
Specification: IS: 14255, IS: 398, IEC 228, BS: 60502, HD: 626, NFC: 33-209
Application: Residential and Commercial Buildings, Multiplexes, Institutional & Industrial applications
Conductor: Copper – Solid/Stranded (Circular) or Flexible-Bare or Tinned ranging 0.5 to 240 sq mm.
Insulation: Natural PVC, HR-PVC, FR, FRLS, LSZH
Outer Sheath : Skin Colour PVC, FR, FRLS
Specifications : IS: 694, BS: 6004, 6500, BS:7211, IEC 60227
Application: Temporary Connections, Wiring Submersible Pumps
Types: Two, Three core with/without ECC ranging from 1-16 sq.mm.
Conductor: Copper – Stranded (Circular) or Flexible – Bare or Tinned
Insulation: PVC, HR PVC
Inner Sheath: PVC, HR PVC
Outer Sheath: PVC, HR PVC
Specification: IS: 694, BS: 6004/6500, BS EN: 60228, BS: 7211
Application: Indoor installation for the interconnection or telephone, electronic equipments.
Conductor: Copper-Solid Bare or Tinned, 0.4, 0.5, 0.63, 0.71 & 0.9 mm up to 100 pairs.
Insulaion: PVC, PE
Inner Sheath: PVC, HR PVC
Armouring: Steel wire / strip
Outer Sheath: PVC, PE, FRLS
Specification: DOT, CW: 1308, BS: 3573, IEC: 60189, G/W1R-06
* To embrace new technologies and methods. * To give unsurpassed products and services to the clients. * To constantly look for improvement and changes.