Highest quality standards are achieved through the implementations of latest technology, decades of experience and everlasting moral values , which have helped us to retain our customers as well as multiply them.
Description | Single Phase |
1.Capacity | 1 KVA to 50 KVA |
2.Input Voltage | 190-270V / 170-270V |
3.Output Voltage | 220/230/240V(Settable) |
4.Nature Of Cooliing | Aircooled/Oilcooled |
5.Output Voltage Regulation | +1% |
6.Efficeincy | >98% |
7.Input Frequency | 50Hz,+3Hz |
8.Effect of Load Power Factor | Nill on output voltage |
9.Speed Of Correction | 30v/Sec |
10.Servo Motor Drive/Type | Ac Synchronus stepper motor & opto coupler based traic drive |
11.Display Type | LCD |
12.Displayed Parameter | Input/Output Voltages,Hz,amps |
13.Protections | Under Voltage/Over Voltage cutoff,Overload and short circuit protection |
14.Type & Control Design | Micro Controlled (DSP) based with O/P Sensing feedback system |
15.Operating Temperature | 0-50 degree celsius |
16.Manual By Pass Facility | Through change over switch above 5kva |
17.Front Panel | Enter,Up/Down key |
18.Distoration of waveform | Nil(Same as Input) |
19.Effect of Load PF | Nil(on output voltage) |
20.Nature of winding | Copper Variacs |
21.Enclosure | CRCA mild steel |
22.Standard of Stabilizer | As per I.S. 9815 |
23.Oil standard | As per I.S 335 |
Description | Three Phase |
1.Capacity | 3 KVA to 2000 KVA |
2.Input Voltage | 295-465V / 330-480V |
3.Output Voltage | 380/400v/415V(Settable) |
4.Nature Of Cooliing | Aircooled/Oilcooled |
5.Output Voltage Regulation | +1% |
6.Efficeincy | >98% |
7.Input Frequency | 50Hz,+3Hz |
8.Effect of Load Power Factor | Nill on output voltage |
9.Speed Of Correction | 60V/Sec |
10.Servo Motor Drive/Type | Ac Synchronus stepper motor & opto coupler based traic drive |
11.Display Type | LCD/LED |
12.Displayed Parameter | Input/Output Voltages,Hz,amps |
13.Protections | Under Voltage/Over Voltage cutoff,Overload and short circuit protection SPP,PRP |
14.Type & Control Design | Micro Controlled (DSP) based with O/P Sensing feedback system |
15.Operating Temperature | 0-50 degree celsius |
16.Manual By Pass Facility | Through change over switch above 100KVA optional |
17.Front Panel | Enter,Up/Down key |
18.Distoration of waveform | Nil(Same as Input) |
19.Effect of Load PF | Nil(on output voltage) |
20.Nature of winding | Copper Variacs |
21.Enclosure | CRCA mild steel |
22.Standard of Stabilizer | As per I.S. 9815 |
24.Reset | Auto/Manual |
25.Event Recorder | Fault Detections Optional |
26.Conections | Input/Output 7way terminal connector. |
23.Oil standard | As per I.S 335 |
* To embrace new technologies and methods. * To give unsurpassed products and services to the clients. * To constantly look for improvement and changes.