Highest quality standards are achieved through the implementations of latest technology, decades of experience and everlasting moral values , which have helped us to retain our customers as well as multiply them.
|
|
INTRODUCTION
It is an economical meter for online measurement of specific Conductivity of solution using a Conductivity cell for RO plant or DM plant applications. It enables to measure the Conductivity without manual balancing and specific Conductivity is read directly on a digital panel. This is available in panel mounting facility in compact size.
Owing to our manufacturing facilities, we offer a wide array of Digital Conductivity MS CD 622 This instrument is a reading meter that measures the solution’s conductivity with the aid of a Conductivity cell. Without the manual balance, the specific conductivity can be read on the digital display. Integrated circuits are included in these instruments and that keep the power consumption low.
Owing to our manufacturing facilities, we offer a wide array of Digital TDS & Conductivity MS CD 610622.This instrument is a reading meter that measures the solution’s TDS & conductivity with the aid of a cell. Without the manual balance, the specific TDS & conductivity can be read on the digital display. Integrated circuits are included in these instruments and that keep the power consumption low.
|
|
|
|
|
|
|
|
|
|
|
|
|
It is a high-precision pH meter for continuous 0-14 pH reading & milivolts.
The pH meter is easy to operate as it has the least number of controls.
CHECK facility saves time from every day buffer standardization and hence is most suitable for quick analysis.
It is a very sleek attractive finished instrument.
MicroSet pH meter is highly precision Instrument using latest art of technology. It Displays three function constantly on 16x 2 LCD i.e. Temp., pH & mill volt on selection. It has the facility for Auto Temp. compensation as well as manually using keys. In mVs mode the instrument can be used for Redox
Potential measurement. Automatic standardization using buffers & keys is made by selecting 7.00,4.00 & 9.20 pH value. Buffers / Electrode slope error are indicated on screen.Optinal printer interface is available for pH & Temp.The Instrument is housed in a very compact ABS plastic cabinet with attractive finish & light weight for handling.pH & Temp. Sensor if open or contact problem is displayed as “OPEN”
|
Top Performance in a Sleek, Lightweight Design
The MS 9535 portable pH meter is one of the most popular pH meters on the market. By utilizing an advanced, custom microprocessor, MS 9535 is able to perform pH, ORP and temperature measurements with high accuracy and fast response.
The mV measurements auto-range and change resolution from 0.1 to 1 mV when readings reach ±699.9 mV.
pH slope changes due to temperature variation are automatically or manually compensated for, from -20 to 120°C (-4.0 to 248.0°F).
The meter has 3 standard buffer values (pH 4.01, 7.01, 10.01), and automatic buffer recognition to avoid errors during calibration. When powered on, the percentage of remaining battery life is indicated on the display pannel.
The HOLD function can freeze the reading on the display to be manually recorded at a more convenient time.
Choose from °C or °F. Users can enable ordisable the Auto-off feature, the acousticsignal and the back-lit display.
In addition, MS 9535 indicates the buffer values used for the most recent calibration.
|
|
|
It is a high-precision ORP meter for continuous mV. The ORP meter is easy to operate as it has the least number of controls. CHECK facility saves time from every day buffer standardization and hence is most suitable for quick analysis.
It is a very sleek attractive finished instrument.
|
It is an economical meter for online measurement of specific TDS of solution using a TDS cell for R.O plant or D.M plant applications. It enables to measure the TDS without manual balancing and specific TDS is read directly on a digital panel. This is available in panel mounting facility in compact size.
Owing to our manufacturing facilities, we offer a wide array of Digital TDS & Conductivity MS CD 610622.This instrument is a reading meter that measures the solution’s TDS & conductivity with the aid of a cell. Without the manual balance, the specific TDS & conductivity can be read on the digital display. Integrated circuits are included in these instruments and that keep the power consumption low.
|
The dissolved oxygen sensor offers the most rugged design for 25 mm side ports. It fits directly into the vessel, eliminating the need for a housing, reducing contamination risks. The modular design allows quick replacement of any part, making it easy to maintain and repair the sensor.
FEATURE
• 316L Stainless Steel
• Sterialized for traceability
• RA32 Finish with Electropolish on wetted parts
• Internal and External Silicone O-rings
• Secured retainer ring
This series of steam sterilizable electrodes are designed for economical use. They are constructed very similar to the standard pH electrodes, have a 10 and 12mm body, and can be ordered with the desired length. Length is determined by the insertion depth on the under side of the fermentor head plate to the tip of the probe. Glass disposable electrodes are available in galvanic styles to fill all requirements. The glass DO probes are available for laboratory fermentation, where sterilization takes place in a separate autoclave. The disposable Dissolved Oxygen Electrodes are compatible with most common oxygen amplifiers. Glass body oxygen electrodes are non temperature compensated and are required to be kept at a constant temperature. Calibration must be made at the same temperature as the controlled fermentation. The electrodes feature external filling tubes. Electrolyte can be added during use without removing the electrode from the vessel. The electrode membranes can be replaced very easily. However, some skill is involved in replacing them.
The dissolved oxygen sensor offers the most rugged design for 25 mm side ports. It fits directly into the vessel, eliminating the need for a housing, reducing contamination risks. The modular design allows quick replacement of any part, making it easy to maintain and repair the sensor.
INTRODUCTION
MS 0257 is a water-resistant, dissolved oxygen meter that measures up to 300% saturation or 45 ppm (mg/L) with temperature compensation and automatic calibration. It has been developed for DO and temperature measurement in water, wastewater, and applications such as fish farming.
This instrument also allows altitude compensation up to 4000 m and the ppm and % saturation are both compensated for changes in solubility of oxygen in water and for permeability of the membrane as well as the temperature effect.
The included polarographic probe features built-in temperature compensation and remov
|
SALIENT FEATURES AND BENEFITS :
• Highly sensitive & stable
• Manual Temperature Compensation
APPLICATIONS :
NATURAL WATER
To ensure the state of dynamic equilibrium of DO maintained by biochemical deplection by bacteria for the food chain and continued re oxy-generation by aeration and photosynthesis and thus the availability
of right amount of DO which is vitally important for flora and fauna in water.
To detect pollution - lower level of DO (normal 7.1 ppm) will adversely affect the aquatic life.
SEWAGE WASTES
To ensure biochemical break-down treatment of sewage which is achieved by bacterial attack which requires DO.Non-availability of DO leads to increase activity of anaerobic, sulphate reducing bacteria resulting in production of hydrogen sulphide causing serious corrosion problem.
MICROBIAL STUDIES
To study effects of drugs on the brain tissues, other organs/limbs, circulation system muscle and connective tissues, malignant tissues and surface.
AGRICULTURE
To ensure sufficient aeration in soil needed for underground respiration of plant roots in addition to photo synthesis.
FOODS & DRUGS
To ensure oxidation is not adversely affecting the food stuffs. To ensure DO requirements for fermentation in foods, distilleries and Bio-synthetic preparations in Drugs & Chemicals.
BOILER FEED WATER
To ensure proper level of DO to avoid oxidative corrosion of Boiler pipes in steam generation, heaters etc.
|
FEATURE
• Full Bore Type
• Simple & cost effective construction
• Provides wide flow ranges
• Outstanding accuracy
• Operates over wide ranges of temperature & pressure
• Easy maintenance as no moving parts
• Pulsed DC coil excitation
• Integral grounding
• Remote Electronics
INTRODUCTION
2-Wire display system with Ultrasonic Level Transmitter is developed by MicroSet with advantages of a variety of similar products, using the latest energy-saving components, the whole current is less than 3.5 mA, it can work in the 9~32 V dc power supply voltage reliably. With LCD display for setting the scene easily.
APPLICATION
Water and Sewage Treatment, Pumping Stations, Collection Wells, Chemical and Biological Reaction Tanks, Sedimentation Tanks, etc. Power, Mining, Slurry pool, Coal Slurry Ponds, Water Treatment, etc.
SALIENT FEATURES
• Non contact type level measurement.
• 2 wire operation.
• Integral LCD Display
• Self diagnostic function i.e. Error message are displayed.
• Automatic temperature compensation.
• Instrument configuration settings are password protected.
• Accuracy 0.25% of F. S.
• Compact size & easy maintenance.
• Reliable & cost effective system.
• Software calibration.
SALIENT FEATURES
• Non contact type level measurement.
• 4 wire operation.
• Integral LCD Display
• Self diagnostic function i.e. Error message are displayed.
• Automatic temperature compensation.
• Instrument configuration settings are password protected.
• Accuracy 0.25% of F. S.
• Compact size & easy maintenance.
• Reliable & cost effective system.
• Software calibration.
With the exception of the 4-20mA sensors, where the length is 220mm, the sensors have a length of 175mm and a diameter of 25mm, with plug adaptor connection.
They are designed to fit into the available flow cells.
The low current produced by the sensors is electronically amplified in the measurement cell.
No zero point calibration is necessary, and measurements can be taken in pressure up to 1 BAR.
The sensors are temperature compensated, and will operate in the range 0 to 45 degrees C (for the 8 Series, 0-55).
The water has to be flowing to obtain a reading, which is why flow cells are recommended.
Changes to the minimum flow rate will only slightly affect the measurement signal.
Surfactants should not be present in the water being measured (does not apply to the 8 Series probes).
For the dual electrode system, the measurement cell is made of gold, and the counter and reference electrodes of silver with silver halogenid coating.
A bias voltage (polarisation) is applied between the two electrodes.
For the potentiostatic 3 electrode system, the measurement electrode is made of gold, the reference electrode is made of silver with a silver halogenid coating, and the counter electrode of stainless steel.
With the exception of the 4-20mA sensors, where the length is 220mm, the sensors have a length of 175mm and a diameter of 25mm, with plug adaptor connection.
They are designed to fit into the available flow cells.
The low current produced by the sensors is electronically amplified in the measurement cell.
No zero point calibration is necessary, and measurements can be taken in pressure up to 1 BAR.
The sensors are temperature compensated, and will operate in the range 0 to 45 degrees C (for the 7 Series, 0-55).
The water has to be flowing to obtain a reading, which is why flow cells are recommended.
Changes to the minimum flow rate will only slightly affect the measurement signal.
Surfactants should not be present in the water being measured (does not apply to the 7 Series probes).
For the dual electrode system, the measurement cell is made of gold, and the counter and reference electrodes of silver with silver halogenid coating. A bias voltage (polarisation) is applied between the two electrodes.
For the potentiostatic 3 electrode system, the measurement electrode is made of gold, the reference electrode is made of silver with a silver halogenid coating, and the counter electrode of stainless steel.
|
* To embrace new technologies and methods. * To give unsurpassed products and services to the clients. * To constantly look for improvement and changes.