Highest quality standards are achieved through the implementations of latest technology, decades of experience and everlasting moral values , which have helped us to retain our customers as well as multiply them.
Product Details:
Minimum Order Quantity 1 Piece
Brand FLOWTECH
Display Digital
Model EMFM-9
Description
Flowtech make electromagnetic flow meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.
Working principle
This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.
Technical detaildescription
Flowtech make electromagnetic flow meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.
Working principle
This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.
Technical detail
Nominal dia (mm) : 15 to 400
Material of construction : ms, ss 304, ss 316 & ss 316l
Electrode material : ss 316, ss 316l, hastelloy ‘c’, & tantalum
Process pressure : max. 25 kg/cm2
Process temperature : max. 150c
Flow tube material : ss 316
End connection : flange/wafer
Flange- standard : ansi b 16.5 150 #rf / 300 # rf
Measuring range : 0.5 m/sec for minimum & 5m/sec for maximum
Accuracy : ± 1% fsd optional: ±0.5% fsd.
Repeatability : 0.3%
Display : 2 line alfa numeric lcd
Display version : integral /remote
Display unit : standard unit in m3, litre
Power supply : 230 vac, 110 vac & 24 vdc
Output : std. 4 – 20 ma
Protection class for sensor : ip 65
Protection class for transmitter : ip 65
Cable length for remote : 10 meters.
Installation : inline flange type
DESCRIPTION
FLOWTECH Make Electromagnetic Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.
WORKING PRINCIPLE
This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.
TECHNICAL DETAIL
Nominal Dia (mm) : 15 to 400
Material of Construction : MS, SS 304, SS 316 & SS 316L
Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
Process Pressure : Max. 25 kg/cm2
Process Temperature : Max. 150C
Flow Tube Material : SS 316
End Connection : Flange/Wafer
Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum
Accuracy : ± 1% FSD Optional: ±0.5% FSD.
Repeatability : 0.3%
Display : 2 Line Alfa Numeric LCD
Display Version : Integral /Remote
Display Unit : Standard Unit in M3, Litre
Power Supply : 230 VAC, 110 VAC & 24 VDC
Output : Std. 4 – 20 mA
Protection Class for Sensor : IP 65
Protection Class for Transmitter : IP 65
Cable Length for Remote : 10 meters.
Installation : Inline Flange Type
Product Details:
Minimum Order Quantity 1 Piece
Model EMFM-0324
Brand FLOWTECH
Description
Flowtech make electromagnetic flow meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.
Working principle
This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.
Technical detail
Nominal dia (mm) : 15 to 400
Material of construction : ms, ss 304, ss 316 & ss 316l
Electrode material : ss 316, ss 316l, hastelloy ‘c’, & tantalum
Process pressure : max. 25 kg/cm2
Process temperature : max. 150c
Flow tube material : ss 316
End connection : flange/wafer
Flange- standard : ansi b 16.5 150 #rf / 300 # rf
Measuring range : 0.5 m/sec for minimum & 5m/sec for maximum
Accuracy : ± 1% fsd optional: ±0.5% fsd.
Repeatability : 0.3%
Display : 2 line alfa numeric lcd
Display version : integral /remote
Display unit : standard unit in m3, litre
Power supply : 230 vac, 110 vac & 24 vdc
Output : std. 4 – 20 ma
Protection class for sensor : ip 65
Protection class for transmitter : ip 65
Cable length for remote : 10 meters.
Installation : inline flange type
Product Details:
Minimum Order Quantity 1 Piece
Brand FLOWTECH
Display Digital
Model EMFM-129
Description
Flowtech make electromagnetic flow meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.
Working principle
This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.
Technical detail
Nominal Dia (mm) : 15 to 400
Material of Construction : MS, SS 304, SS 316 & SS 316L
Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
Process Pressure : Max. 25 kg/cm2
Process Temperature : Max. 150C
Flow Tube Material : SS 316
End Connection : Flange/Wafer
Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum
Accuracy : ± 1% FSD Optional: ±0.5% FSD.
Repeatability : 0.3%
Display : 2 Line Alfa Numeric LCD
Display Version : Integral /Remote
Display Unit : Standard Unit in M3, Litre
Power Supply : 230 VAC, 110 VAC & 24 VDC
Output : Std. 4 – 20 mA
Protection Class for Sensor : IP 65
Protection Class for Transmitter : IP 65
Cable Length for Remote : 10 meters.
Installation : Inline Flange Type
Product Details:
Minimum Order Quantity 1 Piece
Brand FLOWTECH
Display Digital
Model EMFM-122
Description
Flowtech make electromagnetic flow meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.
Working principle
This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.
Technical detail
Nominal dia (mm) : 15 to 400
Material of construction : ms, ss 304, ss 316 & ss 316l
Electrode material : ss 316, ss 316l, hastelloy ‘c’, & tantalum
Process pressure : max. 25 kg/cm2
Process temperature : max. 150c
Flow tube material : ss 316
End connection : flange/wafer
Flange- standard : ansi b 16.5 150 #rf / 300 # rf
Measuring range : 0.5 m/sec for minimum & 5m/sec for maximum
Accuracy : ± 1% fsd optional: ±0.5% fsd.
Repeatability : 0.3%
Display : 2 line alfa numeric lcd
Display version : integral /remote
Display unit : standard unit in m3, litre
Power supply : 230 vac, 110 vac & 24 vdc
Output : std. 4 – 20 ma
Protection class for sensor : ip 65
Protection class for transmitter : ip 65
Cable length for remote : 10 meters.
Installation : inline flange type
Product Details:
Minimum Order Quantity 1 Piece
Brand FLOWTECH
Display Remote
Model EMFM-095
Application Media Water
Line Size 15 NB to 300 NB
Operating Pressure 25 Kg/cm2
FLOWTECH Make Electromagnetic Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.
Working Principle:
This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.
Applications:
Scientific laboratory
Research centres
Chemical industries
Specifications:
Nominal Dia (mm): 15 to 400
Material of Construction: MS, SS 304, SS 316 & SS 316L
Process Pressure: Max. 25 kg/cm2
Process Temperature: Max. 150C
Nominal Dia (mm) : 15 to 400
Material of Construction : MS, SS 304, SS 316 & SS 316L
Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
Process Pressure : Max. 25 kg/cm2
Process Temperature : Max. 150C
Flow Tube Material : SS 316
End Connection : Flange/Wafer
Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum
Accuracy : ± 1% FSD Optional: ±0.5% FSD
Repeatability : 0.3%
Display : 2 Line Alfa Numeric LCD
Display Version : Integral /Remote
Display Unit : Standard Unit in M3, Litre
Power Supply : 230 VAC, 110 VAC & 24 VDC
Output : Std. 4 – 20 mA
Protection Class for Sensor : IP 65
Protection Class for Transmitter : IP 65
Cable Length for Remote : 10 meters
Installation : Inline Flange Type
Product Details:
Minimum Order Quantity 1 Piece
Brand FLOWTECH
Model EMFM-0333
Display Remote
Application Media Water
Operating Pressure 25 Kg/cm2
Line Size 15 NB to 300 NB
Description
FLOWTECH Make Electromagnetic Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.
Working Principle
This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.
Technical Detail
Nominal Dia (mm) : 15 to 400
Material of Construction : MS, SS 304, SS 316 & SS 316L
Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
Process Pressure : Max. 25 kg/cm2
Process Temperature : Max. 150C
Flow Tube Material : SS 316
End Connection : Flange/Wafer
Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum
Accuracy : ± 1% FSD Optional: ±0.5% FSD.
Repeatability : 0.3%
Display : 2 Line Alfa Numeric LCD
Display Version : Integral /Remote
Display Unit : Standard Unit in M3, Litre
Power Supply : 230 VAC, 110 VAC & 24 VDC
Output : Std. 4 – 20 mA
Protection Class for Sensor : IP 65
Protection Class for Transmitter : IP 65
Cable Length for Remote : 10 meters.
Installation : Inline Flange Type
Product Details:
Minimum Order Quantity 1 Piece
Brand FLOWTECH
Display Digital
Model EMFM-0135
FLOWTECH Make Electromagnetic Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.
Working Principle:
This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.
Applications:
Scientific laboratory
Research centres
Chemical industries
Specifications:
Nominal Dia (mm): 15 to 400
Material of Construction: MS, SS 304, SS 316 & SS 316L
Process Pressure: Max. 25 kg/cm2
Process Temperature: Max. 150C
Nominal Dia (mm) : 15 to 400
Material of Construction : MS, SS 304, SS 316 & SS 316L
Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
Process Pressure : Max. 25 kg/cm2
Process Temperature : Max. 150C
Flow Tube Material : SS 316
End Connection : Flange/Wafer
Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum
Accuracy : ± 1% FSD Optional: ±0.5% FSD
Repeatability : 0.3%
Display : 2 Line Alfa Numeric LCD
Display Version : Integral /Remote
Display Unit : Standard Unit in M3, Litre
Power Supply : 230 VAC, 110 VAC & 24 VDC
Output : Std. 4 – 20 mA
Protection Class for Sensor : IP 65
Protection Class for Transmitter : IP 65
Cable Length for Remote : 10 meters
Installation : Inline Flange Type
* To embrace new technologies and methods. * To give unsurpassed products and services to the clients. * To constantly look for improvement and changes.