Featured Products

Highest quality standards are achieved through the implementations of latest technology, decades of experience and everlasting moral values , which have helped us to retain our customers as well as multiply them.

Welcome to ANALAB SCIENTIFIC INSTRUMENTS P.LTD.

Micro P.Hand.M.Vandc.Ando.R.P Analyzer

  /> </div>
<div class=

Supplied with Combination Glass pH Electrode (0-70ºC), Standard Buffer Tablets, Electrode Stand with Clamp, Dust Cover, Power Cord, Operational & Instruction Manual, Manufacturer Test Certificate & Warranty Card

Technical Specifications :

  • pH Range : 0-14 pH
  • Resolution : 0.01 pH
  • Temperature Range : 0.0 to 100ºC (Manual Compensation)
  • Display : 31/2 Digit LED Display
  • Power Supply : 230VAC ±10%, 50 Hz

 

Salient Features :

Calibration check facility & Calibration Error indication for 7.00 & 4.00 pH

 

Conductivity And T.D.S And Resistivity And c Analyzer

  /> </div>
<div class=

Supplied with Conductivity Cell K = 1.0, Temperature Probe, Electrode Stand with Clamp, Dust Cover, DC Adaptor, Operational & Instruction Manual, Manufacturer Test Certificate and Warranty Card.

Technical Specification :

Conductivity Range : 0 to 20.00, 200.0, 2000 µS/Cm; 2 to 20.00, 200.0 ms/cm
Conductivity Resolution : 0.001,0.01,0.1 µS/cm & 0.01, 0.001 mS/cm
TDS Range : 0 to 10.00, 100.0, 1000 ppm; 10.00, 100.0 ppt(1ppt=10,000ppm)
TDS Resolution : 0.001, 0.01, 0.1 ppm & 0.001, 0.01ppt
Range Selection : Auto / Manual Ranging

  • Temperature Range : 0 to 130.0ºC
  • Temperature Resolution : 0.1ºC
  • Temp. Compensation : Automatic & Manual
  • Temperature Coefficient : 0-10.000 % per ºC (Adjustable)
  • Suitable Cell Constant : 0.1, 0.5, 1.0 K
  • Adjustable Cell Constant : 0.09 to 1.1 K
  • Cond. to TDS Conv. Fac.: 0.40000 to 1.00000 (Adjustable)
  • Backlit LCD Display : 16 x 2 line Alphanumeric
  • Printer Capability : Yes - Parallel Port
  • Power Requirement : DC Adaptor

Karl Fischer Titrator

  /> </div>
<div class=

Supplied with 250ml Reaction Vessel, Auto Burette (25 x 0.1ml), 500ml Amber Color Reservoir, Dual Platinum Combined Electrode, Teflon Paddle, Teflon Assembly for holding, Electrode, Moisture Trap, Actuator Assembly, Operational & Instruction Manual and Manufacturer Test Certificate.

Optional :

  • Calibrated 25 ml Auto Burette having Min.Graduation of 0.1ml with Certificate
  • Auto Drain of Reaction Vesselm

Meltingandboiling Point Apparatus

  /> </div>
<div class=

Supplied with Melting Capillary one end sealed (Pack of 100 Nos) , Power Cord and Operational & Instruction Manual and Warranty Card.

Technical Specification :

Detection Principal : Automatic by photocell
Temperature Range : 5ºC Above Ambient to 400ºC
Heating before set point : Automatic Temperature Heating depending upon temp. diff.
Heating after Set point : Variable 0.5, 1.0 & 2.0 ºC - Selectable
Detection of Melting : a) Melting Point b) Melting Range
Oven Controller : Microcontroller Based

  • Temperature Resolution : 0.1ºC
  • Calibration : Multi Point Calibration Standard - as per Pharmacopia or Any users known standard.
  • Max. Heating Time : Less then 10 Minutes from 50ºC to 350ºC
  • Max. Cooling Time : Less then 10 Minutes from 350ºC to 50ºC
  • Melting Capillary : One Capillary (Single Channel)
  • Accuracy of Temp.:
  • Ambient +10ºC to 100ºC………… ± 0.2ºC.
  • 101ºC to 200ºC …………. ± 0.4ºC.
  • 200ºto 350ºC …………….. ± 0.5ºC.

Digital Flame Photometer Modelflamecal

  /> </div>
<div class=

Supplied with two filters (Na and K) , 2 1/2 Digit LED Display, Oil Free Air compressor, Air Filter with Pressure Regulator & Gauge, Atomizer Tube, Gas Lighter, Sample Beaker (05 Nos), LPG Tube, Air line PU Tube etc

Technical Specification :

Range : Na, K, & Li :1-100 ppm and Ca:15-100 ppm

  • Sensitivity : Na, K, & Li :0.5 ppm and Ca:15 ppm
  • Linearity : < 3%
  • Reproducibility : 2% CV for 20 samples
  • Detector : Photo Cell
  • Ignition System : Manual Ignition
  • Flame System : LPG & Dry Oil Free Air
  • Gas Control : Adjustable with Knob
  • Automiser : Axial Flow Type
  • Oil free Air Compressor : Supplied with Built-in Air Filter with Pressure Regulator & Gauge to deliver stable and moisture / oil free air supply.
  • Power Supply : 230 VAC ±10%, 50 Hz

Gas Handling And Purification System

  /> </div>
<div class=

Nitrogen Gas Line Consist of :

  • Moisture Filter consist of Molecular Sieve - 13X & Silica Gel, Length : 11"
  • Regenerable Type Indian Oxytrap
  • Inlet & Outlet Machine Sealed Type Stainless Steel Pressure Gauge
  • Brass Chrome Plated Pressure Regulator with SS Diaphragm
  • Brass Chrome Plated On/Off Valve

Laboratory Gas Generators

  /> </div>
<div class=

Tecnical Specifications :

  • Moisture Content < 2 ppm
  • Oxygen < 5 ppm
  • Total Hydro Carbon < 0.3 ppm
  • CO & CO2 < 2 ppm
  • Purity of Gas : UHP / GC Grade
  • Micron Particulates < 0.01 Micron
  • Capacity of Gas : 300 ml/Min at 6 kg/cm & 800 ml/Min at 6 kg/cm
  • Method of Purification : Pressure Swing Adsorption (PSA)
  • Room Temperature : 5 - 30ºC
  • Supply : 230VAC ± 10%,50Hz

Exhaust Flame Hood

  /> </div>
<div class=

Consist of :

  • SS 304 100 mm dia Pipe with Flange : 3 mtrs
  • SS 304 100 mm dia Bend with Flange : 01 Nos
  • Canopy with Adjustable CFM : 01 No having
  • Dampener : 01 No CFM can be controlled with help of dampner.
  • Blower with Motor : 01 Nos

Ultrasonic Bath (Sonicator)

  /> </div>
<div class=

 


   

  • Electric Supply : 170 – 245 VAC 50Hz Single Phase
  • Ultrasonic Power : As per Model watts average, 1000 Watts peak (with heater)
  • Ultrasonic Frequency : 33 +/- 3 KHz
  • Ultrasonic Generator : Micro Controller base Digital Timer.
  • With latest MOSFET base technology.
  • With Auto Degassing facility.
  • Automatic frequency tuning for maximum output
  • Modular generator for easier modification/servicing.

Our Vision

* To embrace new technologies and methods. * To give unsurpassed products and services to the clients. * To constantly look for improvement and changes.

Site Designed & Maintained by Aman Infotech
Automatic Melting Apparatus, Boiling Point Apparatus, Conductivity And T. D. S And Resistivity And C Analyzer, Digital Flame Photometer Modelflamecal, Exhaust Flame Hood, Flow Diagram For Gas Handling, Gas Control Module, Gas Handling And Purification System, Karl Fischer Titrator, Laboratory Gas Generators, Low Pressure Gas Changeover Module, Meltingandboiling Point Apparatus, Micro P. Hand. M. Vandc. Ando. R. P Analyzer, Ministation, Photo Meters, Purification System With Accessories, Ultrasonic Bath (Sonicator)