The Electrical Motor Driven Main Pump's function is to START automatically when a hydrant valve or sprinkler is activated and to provide adequate quantity of water under pressure to the system.
The capacity of the pump will differ, basis the size of the system. The pump is stopped manually.
Gate valve is used when a straight line flow of fluid and when minimum restriction is desired.
They are named so because the part either stops or allows flow through the valve acts like the opening and closing of a gate.
When the valve is wide open the Gate is fully drawn in to the valve leaving an opening which is same as the size of the pipe, therefore there is only a little pressure drop.
Butterfly valve is light in weight, relatively small, quick acting and provides positive shut off and can be used for throttling.
It has a body, a resilient seat, a butterfly disk, a stem, a packing, a plate and a handle.
To Open or Close, turn the handle only one quarter turn to rotate the disk 90 degree.
As the name implies these are stop valves that use a ball to start or stop the flow of liquid.
When the handle is operated to open the valve, the ball rotates to a point where the hole through the ball is in line with the valve body inlet and outlet.
To shut it requires a 90 degree rotation of the hand wheel or lever, the ball rotates so that the hole is perpendicular to the flow openings of the valve body.
When the pump starts the ball moves to open position and enables the liquid flow without any hindrance.
When the pump stops the balls takes the firm position against the metal seat because of its weight and back pressure.
Is fitted on the delivery line and the water cannot flow backwards and opens when the water flows.
ICV is installed outside the structure of the protected premises is also called as Alarm Valve.
It has NRV, Gong, Screw valve, Control valve, Pressure Gauge, Y Strainer and other fittings.
It is fixed in large sprinkler systems and is use to control the water supply and the operation of system.
Fire Pump Control Panel consists of electrical components like Circuit Breaker, Switches, Relays & other components dedicated to the operation of pumps.
The components installed in the panel receives signal from alarm devices like Pressure Switch and activates motor control devices to provide power to fire pumps and monitor its performance.
The function of the Pressure Switch is to energize or de-energize the electrical circuits and check whether the pressure is normal or abnormal.
When the pressure drops down the prescribed level, it triggers an electrical circuit. All the pumps requires 1 Pressure Switch each.
Major Brands : Indfoss
Is designed specially for fixing on hydrant stand posts or on a specially built trolley in case if portable units.
The monitor rotates 360 degrees and elevates between 150 degree to -20 degree with a water flow rate of up to 2700 lpm at 7kgf/cm2.
These are used in Oil Refineries and Chemical Plants.
|