Highest quality standards are achieved through the implementations of latest technology, decades of experience and everlasting moral values , which have helped us to retain our customers as well as multiply them.
Specifications:- Input:- Thermocouples/ Pt-100 (RTD). Ranges:- As Per Application. Indication:- 7 Segment LCD 3. 5 Digit 1/2″ Size Accuracy:- ± 0. 5% of FSD ±1 Digit. Supply:- 9V Battery Operated Input Connector:- Rf/3pin/Omega Features:- Accepts All Types of Input. Battery Operated, Low Battery Indication. Accurate Compact and Reliable. Light Weighted. At Reasonable Cost Easy to…
Specifications:- Input:- Thermocouples/ Pt-100(RTD). Ranges:-As Per Application. Indication:- 7 Segment LCD 3.5 Digit 1/2″ Size Accuracy:- ± 0.5% of FSD ±1 Digit. Supply:- 9V Battery Operated No. of Channels:- 8, 6 or 12 Channel Channel Selection:- Multi-Point Switch Input Connector:- Rf/3pin/Omega.
Specifications:- Input:- Thermocouples/Pt-100(RTD) Range:- As Per Application. No. of Channels:- 6, 8 or 12 Channels Channel Selection:- Multi-point Switch Indication:- Seven Segment LED 3.5 Digit 1/2″ Size. Accuracy:- ±0.5% of FSD Supply:- 230VAC ±10% Cut Out:- 92x92x110mm.
Specification:- Input:- Thermocouple(J,K,R,S) RTD(Pt-100) cj compensation for t/c electrical & automatic. Range:- As per application. Indication:-Seven Segment LED 3.5 Digit 1/2″ size. Accuracy:- ±0.5% of FSD Supply:-230VAC ±10% Cut Out:- 72X72mm, 48X96mm, 96X96
Specifications:- Input :- RTD (Pt-100) & Thermocouple ‘K’ (Cr-al). Range :-As per your requirement. Indication :- 3½ Digit Seven Segment LCD ½”size. Accuracy of Indication :- ±0.5% of FSD ± 1digit Operating Temperature :- 0ºc to 50ºc Supply :- 9VDC (Battery) Probe Dia. :- 6.35mm, 8mm, and 9.5mm or as per your application. View Product Process Indicator MC Specifications:- Input:- Thermocouples/ Pt-100(RTD) Range:- As per application. Indication:- Seven segment LED 3.5 digit 2″ Big Display. Accuracy:- ±0.5% of FSD Operating Temperature:- 0°c to 50°c Supply:- 230VAC/ 24VDC ±10% Interface:- RS232 Interface. Size:- 280mm×230mm×45mm (W×H×D) View Product Large Display Indicator Specifications:- Input:- ‘K’ , ‘J’ , ‘RTD’ Range:- As Per Application. Indication:- Seven Segment LED 3.5 Digit 2″ Size. Accuracy:- ±0.5% of FSD Operating Temperature:- 0°C to 50°c Supply:- 230VAC ±10%. Size:- 245 x 145mm. View Product Temperature Humidity Indicator Specifications:- Input:- Pt-100(RTD) Humidity Range:- 0 to 100%Rh Temperature Range:- -4ºC to 200ºC Indication:- Seven Segment LED Big Display. Accuracy:- ± 2%( 0-90%Rh), ±3%( 90-100%Rh) Resolution:- 0.1%Rh Power Supply:- 24VDC/230VAC, 50Hz. Size:- 265mm×230mm×90mm(W×H×D) View Product Process Indicator Specifications:- Input: 0 to 10 VDC Viewing Range: 0.0 to 75.0 LPM Supply: 230VAC Indication: 4Digit 7Segment 1” LED Display. Auxiliary Power Supply: 24VDC, 5Amp. Cheesy Size: 2U x 41T x 220mm Application: Blow Meter. View Product Flame Proof Indicator Flameproof temperature indicator is having wide application in chemical, oil plants, fertilizer, petrochemical where accurate temperature indication is required in highly inflammable atmosphere. Specification:- Input:- Thermocouples/ Pt-100(RTD) Range:- As per application. Indication:- Seven segment LED 3.5 digit 1/2″ size. Accuracy:- ±0.5% of FSD Operating temperature:- 0°C to 50°C. Supply:- 230VAC ±10% View Product Yudian Digital Temperature Indicators Specifications:- Input: RTD/Thermocouple. Range: For thermocouple- 0 to +999 ºC, For RTD(Pt-100)- 0 to 800 ºC Accuracy: 0.3% ±1ºC Power Supply: 230 VAC/ 24 VDC ±10% Indication: Seven Segment 3.5Digit LED Display. Operating Temperature: -10 to +60 ºC, Humidity: 0 to 90 %Rh Size: 96x96mm, 160x80mm, 72x72mm, 48x48mm, 48x96mm, 96x48mm View Product REQUEST A QUOTE Send Us Quick Message Fields marked with an * are required Name * Email * Message * Yog Electro Process Pvt Ltd Plot no. G, 63/8,MIDC Chakan, Phase III, Tal. Khed, Maharashtra 411501
Specifications:- Input:- Thermocouples/ Pt-100(RTD) Range:- As per application. Indication:- Seven segment LED 3.5 digit 2″ Big Display. Accuracy:- ±0.5% of FSD Operating Temperature:- 0°c to 50°c Supply:- 230VAC/ 24VDC ±10% Interface:- RS232 Interface. Size:- 280mm×230mm×45mm (W×H×D)
Specifications:- Input:- Pt-100(RTD) Humidity Range:- 0 to 100%Rh Temperature Range:- -4ºC to 200ºC Indication:- Seven Segment LED Big Display. Accuracy:- ± 2%( 0-90%Rh), ±3%( 90-100%Rh) Resolution:- 0.1%Rh Power Supply:- 24VDC/230VAC, 50Hz. Size:- 265mm×230mm×90mm(W×H×D)
Flameproof temperature indicator is having wide application in chemical, oil plants, fertilizer, petrochemical where accurate temperature indication is required in highly inflammable atmosphere. Specification:- Input:- Thermocouples/ Pt-100(RTD) Range:- As per application. Indication:- Seven segment LED 3.5 digit 1/2″ size. Accuracy:- ±0.5% of FSD Operating temperature:- 0°C to 50°C. Supply:- 230VAC ±10%
Specifications:- Input: RTD/Thermocouple. Range: For thermocouple- 0 to +999 ºC, For RTD(Pt-100)- 0 to 800 ºC Accuracy: 0.3% ±1ºC Power Supply: 230 VAC/ 24 VDC ±10% Indication: Seven Segment 3.5Digit LED Display. Operating Temperature: -10 to +60 ºC, Humidity: 0 to 90 %Rh Size: 96x96mm, 160x80mm, 72x72mm, 48x48mm, 48x96mm, 96x48mm
Specifications: Input: RTD (2 Core) Range: 0.0 Deg C to 400.0 Deg C Indication: 4 Digit Seven segment 1/2″ LED Display. Output: 2Relays (Potential Free) to control pump. Accuracy: ±0.1% of FSD Application: To maintain the set temperature & circulate the water in solar water heating system
Specifications:- Input:- RTD (Pt-100), Thermocouples (‘J’, ‘K’, ‘S’, ‘‘R’) etc. Range:- As per your application. Indication:- Seven Segment LED 3.5 Digit ½” Size. Accuracy of Indication:- ± 0.5% of FSD ± 1 Digit Control Accuracy:- 1ºc Nominal (Can Be Adjusted). Relay:- Contact Rating 5Amps/250VAC/12VDC Operating Temperature:- 0ºC to 50ºC Supply Voltage:- 230VAC ± 10% Keyboard:-
Specifications:- Input:- Thermocouples/ Pt-100(RTD) Range:- As Per Application. Indication:- Seven Segment LED 3. 5 Digit 1/2″ Size. Accuracy of Indication:- ±0. 5% of FSD Control Accuracy:- 1ºC Nominal (Can Be Adjusted) Relay:- Contact Rating 5Amps/230VAC/ 12VDC Supply:- 230VAC ±10% Size:- 96x96mm.
Specifications:- Input:- RTD (Pt-100), Thermocouples (‘J’, ‘K’, ‘S’, ‘R’) Range:- As per your application. Indication:- Seven segment LED 3. 5 digit ½” size. Accuracy of indication:- ± 0.5% of FSD ±1 digit Control accuracy:- 1ºC nominal (can be adjusted) Relay:- Contact rating 5 Amps/ 250VAC/ 12VDC Operating temperature:- 0ºC to 50ºC Supply voltage:- 230VAC ±
Specifications: Input:RTD (Pt-100), Thermocouples (J, K, R, S) etc. Range: As per your application. Indication:- Seven Segment LED 3.5Digit ½” Size. Accuracy of Indication:- ±0.5% of FSD ±1Digit. Control Accuracy:- 1ºC to Nominal (Can be adjusted). Relay:- Contact rating 5Amps/250VAC/ 12VDC. Operating Temperature:- 0ºC to 50ºC Supply Voltage:- 230VAC ± 10% Size:- 96x96mm
Applications:- Left control, Packaging Machine Control (Fill Form Machine Control), Synchronization, Line Automation etc. Features: 1. It have 12 Digital NPN type inputs & 8 numbers Digital NPN type outputs. We can program number of recipes/ Delays such as cure time, close time, open time, clamp delay, hold delay etc. 2. Number of cycle count…
Flameproof temperature controller is having wide application in chemical, oil plants, fertilizer, petrochemical where accurate temperature indication is required in highly inflammable atmosphere. Specifications:- Input:- Thermocouples/ Pt-100(RTD) Range:- As per application. Indication:-Seven segment LED 3.5 digit 1/2″ size. Accuracy of Indication:- ±0.5% of FSD ± 1 digit. Control accuracy:- 1ºC nominal (can be adjusted) Relay
Specifications:- Input:- RTD (Pt-100), Thermocouples (Fe-con ‘J’/Cr-al ‘K’/ Pt-Pt-Rh 10% ‘S’/ Pt-Pt-Rh 13% ‘R’) etc. Range:-As per application. Indication:- Seven Segment LED 3.5 Digit ½” Size. Accuracy of Indication:- ± 0.5% of FSD ± 1 Digit Operating Temperature:- 0ºC to 50ºC Supply Voltage:- 230VAC ± 10%
Specifications:- Input:- Thermocouple (K,J,T,E,N)/ Pt-100 Accuracy:- 0.3%FS ±1°C Display Resolution:- 0 or 0.0 (0.0 just for o to 99.9 Display) Alarm Function:- High Alarm, Lower Limit Alarm, Deviation High Alarm. Power Supply Voltage Rating:- 100-240VAC, -15%, +10% / 50-60Hz. Power Consumption:- -10-+60°C Humidity: 0~90RH% Size:- 96x96x100mm/ 72x72x95mm/ 48x48x95mm etc..
Technical Specification: Input: Pt-100 / J / K Operating Temp: 0 oC to 50 oC Number or Channels: 8 Channels Power Supply: 230Vac +/- 10% Channel Indication: WithNumber Resolutions: 0.1/1 oC Scan Time: 5 to 60 Sec [Adjustable] Indication: 4 Digits, 7 Seg. LED 1/2’’ Size Display Display Mode: Auto / Mode Size: 96 X 96mm
Specifications:- Inputs :- RTD, R, S, K, J. (Selectable) Display Power Supply :- 230 VAC (50Hz) ± 10% Alarm Output :- Common Relay output for all channel. No. Of channel available :- 8, 16, 24, 32 channel etc. Online data recording :- For each channel is up to 500 / 1000 Recording interval :- 1 to 9999 MIN. Manual view scan time :- 1 to 200 SEC. Adjustable Mode :- Auto manual hold. Interface:- RS232 / 485 interface printer output. Memory capacity: 16 MB max expandable to 512 MB max (optional). Resolution: 0. 1 ºC up to 1600 ºC. Dimensions: 72 x 72 mm.
Specifications:- Input: Proximity S/W or potential free contacts Display:4+4 Digit, 0.56″,Red LED Output: 1 C/O, 5A/10A resistive relay Supply: 230V/100VAC, ±10%, 50/60Hz Set Range: 0~9999 counts No. of Batches: 0~9999 batches Total Counts: 0~999999 counts Count Direction: UP Size: 72x72x113mm. (6 Digit Counter also available)
Specification:- Features:- Panel Mounting Field mounting (Optional) Highly stable Analog design. Multi tone Compact & cost effective. Technical specifications:- Input:- 4-20mA, 0-20mA, 0-1VDC, 0-5VDC, 0-10VDC etc. Output:- 4-20mA, 0-20mA, 0-1VDC, 0-5VDC, 0-10VDC etc. (Single/Dual) Sound Level:- 80-90 Db Accept:- On front & Back Tone:- 3 Nos. Selection with switch supply:- 230VAC +/- 10% Ambient operating temperature range:- 0 to 50°C Operating humiditi limit:- 10 TO 90%, Non-Condensing.
Features: Head mounting/ Rail Mounting Highly stable Analog design. Built in ‘cold junction compensation’ for Thermocouple. Linearization & 3rd wire compensation for RTD. Wide supply voltage range Compact & cost effective. Technical Specifications Input :- Pt-100 RTD, 2 or 3 Wire. / Thermocouple Output :- 2 Wire 4 to 20mA Corresponding to Defined Input Temperature Range. Operating Voltage :- Nominally 24VDC, Can Range from 12V to 36V. Maximum Load in Loop:- Vin-8/20 Basic Accuracy:- +/- 0.25% for RTD , +/- 75% for Thermocouple. Linearization Circuitry Error:- <0.05% of Span at Any Current. Ambient Temperature Operating Range:- 0 to 50° C. Indication(S):- Red LED “ON” Indicates That Unit is Operating in Loop. Protection:- Reverse Polarity Protected to 500V Surge Suppression at 50VDC Operating Humidity Limit:- 10 to 90%, Non-condensing. Material of Encapsulation:- Epoxy.
The Humidity sensor reacts very quickly on humidity leaps and measures accurately and free of any hysteresis. These characteristics suits especially good for a precise and quick control of the room climate. These are compact Transmitters for humidity, temperature and combined humidity / temperature with excellent price / performance ratio. Advantages: Calibration free Ready to use Precise humidity measurement Drift stable thanks to wide sensor area Available with optional temperature sensor Smallest dimensions Mechanical robust and easy to integrate Different output options on request Technical Data: Measurement Principle :- Capacitive humidity sensor Humidity measurement range :- 0 to 100%Rh Operating temperature :- -25 to +85°C Operating voltage :- 8 to 32VDC Current consumption : 4 to 20mA Output signal :- 4 to 20mA (0 to 100%Rh) Temperature sensor :- optional Pt100/Pt1000. Accuracy :- < 3% Rh Terminal connectors :- Soldering terminals for VCC, Analog out 4 to 20mA, Loop-through of optional temperature sensor.
Specifications:- Input :- Pt-100RTD, 2 or 3 wire. / Thermocouple. Output :- 2 wire 4 to 20 mA corresponding to defined input temperature range. Operating Voltage :- Normally 24VDC,can range from 12V to 36V. Basic accuracy :- 0.5% of FSD Change of current o/p with Ambient Temperature :- <± 0.01% for span per ºC change Change of current o/p with supply voltage :- < ± 0.001% of span per volt, from 12V to 3V. Linearization Circuitry Error :- < 0.05% of span at any current. Ambient Operating Temperature Range :- 0ºC to 70ºC Indication :- Red LED “ON” indicates that units is operating in loop. Operating Humidity Limit :- 5 to 90%, Non-condensing. Material of Encapsulation :- Epoxy.
Pressure transmitters translate low-level electrical outputs from pressure sensing devices to higher-level signals that are suitable for transmission and processing. They use many different sensing technologies and can measure the pressure of liquids and/or gases. Elastic elements when subjected to pressure get deformed. This deformation when measured gives an indication of the applied pressure. These elements may be in the form of Diaphragm, Bourdan Tube, Capsules, Bellows, and Helical Tube. Etc. These deformations can be measured by mechanical means. Features Head or Rail Mounting. Field mounting (Optional) Highly stable Analog design. Built in ‘cold junction compensation’ for thermocouple. Linearization & 3rd wire compensation for RTD. Wide supply voltage rang Compact & cost effective. Technical Specification Input : Pt-100 RTD, 2 OR 3wire. /Thermocouple Output : 2 wire 4 to 20mA corresponding to defined input temperature range. Operating Voltage : Nominally 24 VDC, can range from 12V to 36V. Maximum Load in Loop : 250 Ohm for 24VDC supply. Basic Accuracy:- +/- 0.5% of FSD. Ambient Operating Temperature Range:- 0 to50°C. Indication(s):- Red LED “ON” indicates that unit is operating in loop. Material of Encapsulation:- Epoxy.
Specifications:- We offer the range of Temperature transmitter having highly stable analog output (Current: 4-20mA) for Thermocouple & Pt-100 Input. Technical Specifications Input :- Pt-100 RTD, 2 or 3 Wire. / Thermocouple Output :- 2 Wire 4 to 20mA Corresponding to Defined Input Temperature Range. Operating Voltage :- Nominally 24VDC, Can Range from 12V to 36V. Maximum Load in Loop:- Vin-8/20 Basic Accuracy:- +/- 0.25% for RTD , +/- 75% for Thermocouple. Linearization Circuitry Error:- <0.05% of Span at Any Current. Ambient Temperature Operating Range:- 0 to 50° C. Indication(S):- Red LED “ON” Indicates That Unit is Operating in Loop. Protection:- Reverse Polarity Protected to 500V Surge Suppression at 50VDC. Operating Humidity Limit:- 10 to 90%, Non-condensing. Mounting:- Din Rail Mounting. Material of Encapsulation:- Epoxy.
We offer the range of Temperature transmitter having highly stable analog output (Current: 4-20mA) for Thermocouple & Pt-100 Input. Technical Specifications Input :- Pt-100 RTD, 2 or 3 Wire. / Thermocouple Output :- 2 Wire 4 to 20mA Corresponding to Defined Input Temperature Range. Operating Voltage :- Nominally 24VDC, Can Range from 12V to 36V. Maximum Load in Loop:- Vin-8/20 Basic Accuracy:- +/- 0.25% for RTD , +/- 75% for Thermocouple. Linearization Circuitry Error:- <0.05% of Span at Any Current. Ambient Temperature Operating Range:- 0 to 50° C. Indication(S):- Red LED “ON” Indicates that unit is operating in loop. Protection:- Reverse Polarity Protected to 500V Surge Suppression at 50VDC. Operating Humidity Limit:- 10 to 90%, Non-condensing. Probe Diameter:- 4.7mm, 6.35mm,8mm etc. As per your application. Material of Encapsulation:- Epoxy.
Specifications Diaphragm Type: HP: -1 to 0 kg/cm & 0 to 10 kg/cm LP : -6000 mmWC to 0 & 0 to 6000 mmWC Accuracy: ±1.6% of F.S. Ambient Temperature: -20 Deg C to 65Deg C. Process Temperature: max 100 Degree C. OPerating Pressure Range: 75% of scale value. Over pressure limit: 125% of scale value. Gauge connection: 1/2″ BSP.
Specifications: Accuracy: ±1.0% of FS. Ambient Temperature: -25 Degree to 65 Degree Process Temperature: Max 300 Degree C. Operating Pressure Range: 75% of scale value. Over pressure Limit: < 100 bar : 125% of Max. Scale Value >100 to < 600 bar : 115% of Max. Scale Value > 600 to < 1600 bar : 110% of Max. Scale Value Protection: IP65
Our 100mm panel mounting micro glycerin filled pressure gauges are ideal for dampening the effect of vibration & pulsation. It also lubricate the movement and internal parts which extends the lite of gauge. It enhance the reliability and integrity of measuring system for long periods under extreme operating condition.
Specifications:- Input :- RTD (Pt-100) & Thermocouple ‘K’ (Cr-al). Range :-As per your requirement. Indication :- 3½ Digit Seven Segment LCD ½”size. Accuracy of Indication :- ±0.5% of FSD ± 1digit Operating Temperature :- 0ºc to 50ºC Supply :- 9VDC (Battery) Probe Dia. :- 6.35mm, 8mm, and 9.5mm or as per your application.
* To embrace new technologies and methods. * To give unsurpassed products and services to the clients. * To constantly look for improvement and changes.