Highest quality standards are achieved through the implementations of latest technology, decades of experience and everlasting moral values , which have helped us to retain our customers as well as multiply them.
COOLING TOWER CHEMICAL:
Whether your cooling tower is large or small, it has chemical treatment requirements that must be met accurately and reliably to control corrosion, scale and deposits. Chemicals injected include:
Corrosion inhibitors
Scale inhibitors
Dispersants
Biological control agents
Coagulants
Flocculants
Until now, your choices in treatment systems were limited:
You could obtain an unreliable, minimum-capability system from your chemical supplier…
Or you could spend your design resources on a custom-built system.
Either way, it was hard to get the right combination of capability and cost.
We have Solution for above problems they are:
The primary objective of cooling water treatment is to facilitate as heat rejection & minimize water consumption. Cooling involves heat transfer of heat (Btu’s Kcal / Kg) from one substance to another.Cooling water for the industries if untreated cause several problem i.e. corrosion, Scaling, fouling & Microbiological growth in Cooling Towers, & other parts, resulting in production loss, equipments failure & breakdowns.
Aquablend-292 is a liquid blend of molybdate & nitrite base along with a pH buffer. The product is recommended for use in closed component Cooling system like Chillers & genset system. the product is also applicable to hood / jacket cooling in steel industry
The primary function of a boiler is to transfer heat from hot gases generated by the combustion of fuel into water until it becomes hot or turns to steam. The steam or hot water can then be used in building or facility processes.
Except for a small number of specialty models, boilers generally fit into one of the two common categories: fire-tube boilers and water-tube boilers.
Fire-tube boilers pass hot combustion gases through tubes submerged in water. Water-tube boilers, on the other hand, circulate water inside the tubes in a closed vessel filled with hot combustions gases. In either category the boiler feed water and fuel often contain impurities, which impairs boiler operation and efficiency. Chemical additives can be used to correct the problems caused by these impurities. To improve feed water quality, fuel oil condition, and steam purity, these chemicals can be injected directly into the feed water, steam or fuel oil.
R.O. CHEMICALS:
RO System if untreated cause several problems like inorganic, colloidal & bio fouling resulting in reduced permeate recovery, increased pressure differential & permeate conductivity, frequent membrane cleaning ultimately premature membrane failure. Scaling elements like carbonates, Sulphates, Silicates, iron, fluoride & aluminium are highly effective threshold agent inhibit precipitation of these salts by increasing their their solubility limit. It is also acts as iron sequester thereby iron fouling .
Resin is a natural or synthetic compound which begins in a highly viscous state and hardens with treatment. Typically, resin is soluble in alcohol, but not in water. There are a number of different classes of resin, depending on exact chemical composition and potential uses. There are numerous applications for resins, ranging from art to polymer production, and many consumers interact with products which contain resin on a daily basis.
3 Steps for Resin Cleaning for Softner & DM -
1. Backwashing Phase: This removes dirt from the mineral tank and is part of the regeneration process
2. Regeneration Phase: The mineral tank is recharged with sodium from the brine tank solution and displaces calcium and magnesium,
which is then washed down the drain during the Backwashing Phase.
3. Rinse Phase: The mineral tank is rinsed with fresh water and loads the brine tank so that it is ready for the next cycle.
Purpose of chemical cleaning :
The primary reasons for chemical cleaning of boilers/ heat exchangers are to prevent tube failures & improve unit availability. Tube failures in low pressure boilers/heat exchangers are normally the results of creep which occurs when internal deposits produce excessive metal temperature. A relatively smaller quantity of deposit creates difficulties in high pressure boilers. Caustic corrosion & hydrogen damage, which occur only in the presence of deposits, may cause tube failures at temperatures well below the creep limit. Deposits originating both from fabrication & during operation should be considered potential problems.
THERMIC FLUID DECARBONISING CHEMICAL:
Thermic Fluid is the heating media which transfer the heat in close loop cycle.
It is available in two forms……….
Mineral heat transfer oil.
Synthetic heat transfer oil.
Mineral oil can withstand maximum temperature up to 280˚C. Synthetic oil can withstand maximum temperature up to 310˚C.
Continuous use of thermic fluid systems results in to deteriorating of Thermic fluid.
The main causes for deterioration are oxidation & cracking.
Oxidation: Oxidation at higher temperatures causes formation of sticky carbon. This causes choking of the system & reduced heat transfer efficiency & also produces acidic products. These add to viscosity of the oil along with increase in corrosion rate at internal parts of thermic fluid heating system.
ION EXCHANGE RESINS
We offer a wide range of Ion Exchange Resin, which is extensively used for different separation, purification and decontamination processes. Our range of Ion Exchange Resin is useful for cation & anion resins for Softening, DM & Mix Bed Resin for producing Ultra Pure Water. These are of quality standard and are available at very competitive price. As the name implies ion exchange is a process in which undesirable ions are exchanged for more desirable irons. This plant removes all the impurities and hardness present in the water and makes it soft and skin friendly.
Description / Specification of Special Resin For Drinking Water Iron And Arsenice Removal.
We are involved in offering a wide range of Special Resin For Drinking Water Iron And Arsenice Removal. to our most valued clients. Our range of these are widely appreciated by our clients which are situated all round the nation. We offer our range of it at most affordable prices.
We introduce ourselves as an eminent trader and supplier of an extensive array of Special Resin For Drinking Water Iron And Arsenice Removal.. Prior to dispatch, our quality controllers run numerous tests on the entire range on various parameters of quality and durability. The offered equipment is manufactured using superior quality components with the aid of sophisticated techniques at the vendors' end. Moreover, our precious clients can purchase it in different technical specifications at reasonable price from us within promised time frame.
Features:
Sturdy design
Highly durable
Application specific design
ACTIVATED CARBON – Activated Carbon is porous from of Carbon manufactured from internal surface area.
The porosity Creates a remarkable power of Adsorption, an indispensable Process in industrial separation.
Purification, decolonization & recovery technique. The Carbon atoms at the internal surface of Activated Carbon.
Exert an attraction ( Vendor waars force ) on the molecules of surrounding liquid & gas & fixes on to its pore walls.
This is the basis of mechanism whereby Activated Carbons may be used to remove one or more components from a mixture.
GRANULES – In GASPHASE adsorption, Granular Carbon is almost always used because the Pressure drop in the Carbon bed is of prime importance & Granular Carbon will allow sufficient flow with an acceptable pressure drop.
We offer a wide range of Polyelectrolytes, which is vastly used as emulsifiers, thickeners in various areas such as food, cosmetics, shampoo and soaps. These Polyelectrolytes have water solubility features and thus these are highly demanded in medical and bio-chemical sectors for further processing into various components. Our range of polyelectrolyte is available in different types such as anionic & cationic as well as in non-ionic polyekectrikttes type.
Polyelectrolyte is widely used to purify drinking water, treat waste water, produce paper, extract precious minerals and cover a whole host of other applications. Synthetic polyelectrolyte is essential for health as well as for environmental benefits.
COAGULANTS/ FLOCCULANTS ARE AVAILABLE FOR ETP & RAW WATER TREATMENT.
Ozone is "active oxygen", nature's special element and a beautiful gift to mankind. Ozone is a triatomic allotrope of oxygen formed by recombination of oxygen atoms. It is a colourless gas with characteristic pungent odor and can easily be detected at low level of 0.05 ppm. It is a very strong oxidant and is over 3000 times more powerful disinfectant than chlorine. It disinfects, oxidizes, deodorizes and decolorizes.
Ozone is generated by an electrical discharge through dry air or pure oxygen and is generated onsite because it decomposes to elemental oxygen in short amount of time.
AQUASOL are complete systems available in one package, for reliable testing. Any time... Anywhere...
AQUASOL systems are extremely simple and easy to use. You neither have to be a trained chemist nor require any experience to get reliable results from these systems. AQUASOL makes monitoring convenient and quick. Thus preventive action can be taken immediately.Based On Proven Laboratory Methods Backed By Sound Chemical Research
AQUASOL are systems based on standard and established analytical methods, backed by chemical research. These are simple adaptations of classic chemical analytical methods. The analytical methods are based on Standard Methods For Examination Of Water And Waste Water prepared by American Public Health Association (APHA), American Water Works Association (AWWA), different pharmacopoeias and other standard methods. You can have complete confidence in the results you obtain from AQUASOL, as they are extremely reliable.AQUASOL systems replace conventional analytical methods such as Titrimetric, Colorimetric and Spectrophotometric by simple drop test & standard colour comparison methods.
AQUASOL reagents are completely ready to use, conveniently packed, and therefore user friendly.Now you do not have to bother about reagent preparations and standardization.Our drop count procedures and suitable colour comparisons are also economical.
AQUASOL Gives You Freedom From The Need Of A Laboratory, Trained Manpower And Laborious Processes Involved.
If you are still using Oversized 6 lph pumps and operating them at low frequencies If you are you filing your Chemical Tanks Too Frequently
If you are Diluting your Solutions too much Achieve Better Accuracy, Finar Control and Longer Life with New e Dose of 1 lph / 1.5 lph and 3 lph capacity
* To embrace new technologies and methods. * To give unsurpassed products and services to the clients. * To constantly look for improvement and changes.