Highest quality standards are achieved through the implementations of latest technology, decades of experience and everlasting moral values , which have helped us to retain our customers as well as multiply them.
We manufacture all type of fire extinguisher like A B C Type Dry Powder Fire Extinguisher, CO2 Fire Extinguisher, Dry Powder Fire Extinguisher, Mechanical Foam (Afff) Fire Extinguisher, Modular Automatic Fire Extinguisher, Water CO2 Type Fire Extinguisher, Clean Agent Fire Extinguisher and all kind of Fire Fighting Equipments. We provide complete Fire Extinguisher products range and after sales services on all India bases.
Having a name for quality, we have been supplying to various blue chip organisations like IOCL, BPCL, HPCL, ONGC, GAIL Etc.
Our extinguishers are ideally used in Industries, Organisations, Plants and Refineries, Chemical and Hazardous setups, Residential Buildings, Homes and cars.
Supremex’s main focus being quality, the extinguishers go through various checks, testing and inspection procedures to be the kind of fire extinguisher which will be of use, in case of a fire.
How hard can it be for a company to protect itself against fire accidents? For most companies, it can be harder than one would think. Since most of them don’t even worry about this issue so much, they don’t take the necessary precautions to protect themselves against possible accidents. However, if you are a person who wants to do their best to protect the business, you need to contact our company, Extinct Fire Engineers. Unlike any other Fire Fighting Company In India that sells fire protection products and services, we are Crisil certified.
About two decades ago, we decided that it was time for someone to provide the best fire fighting products and services in India. We have become one of the best fire fighting companies that are ISO 9001 certified. Up until now, we have successfully completed more than 500 projects for our customers. This has done a lot for our reputation, which means that we enjoy success simply by word of mouth. We make sure that our employees have the latest knowledge. That is why we give them a comprehensive training every month and we also provide competitions and prizes to keep them motivated. That way, they are able to continue providing top quality results.
You should choose us because we have a lot of experience and we know what works and what doesn’t in this industry. We will examine your profile and work with you towards a mutual decision about the best fire protection system for your property. The safety of your property is our number one concern and we also make sure not to interrupt your work in any way. So far, we haven’t been blacklisted by any client or consultant, something that cannot be claimed by most fire fighting companies in India. Our company is officially registered with the Maharashtra government and we continuously focus on Quality Management Systems and Safety.
You need a versatile, easy-to-use commercial fire detection and alarm system that provides greater control over building safety — and our solutions deliver. We offer advanced fire detection systems designed to meet the needs of everything from single, stand-alone facilities to complex, networked campus environments. Our fire detection systems can integrate with Johnson Controls building and security management systems, providing far greater control over building protection and performance.
The fire alarm panel is the central element of any fire alarm system. All devices (detectors, call points, sounders, etc.) are connected to the fire panel, which typically provides power to them and information is relayed back and forth to determine whether there is a fire and if so activate an appropriate warning.
If you're not too sure which fire alarm panels are suitable for your needs, there are several factors that should be considered. Any fire alarm system that has been designed to the British standard BS 5839 will divide the property up into zones (physical areas which can be identified by a zone number used to locate the fire). Every fire alarm panel will have a zone capacity and this must be sufficient to accommodate however many zones your system needs.
Secondly do you know what type of system you need to install? Broadly speaking there are 3 types of fire panel; conventional, 2 wire or addressable and each is summarised as follows;
Conventional fire alarm panels are considered the most basic and economical in terms of the equipment itself. Detectors and call points for each zone are connected in series, which ends at the last device and terminates at the panel (radial circuit). Warning devices (sounders and flashers) must be connected to a separate sounder circuit. In the event of a fire the panel will simply show which zone this has occurred in (it is worth considering that a single zone may contain up to 32 detectors).
2 wire fire alarm panels can be thought of as an evolution of conventional panels. To overcome the additional cabling needed for the separate sounder circuit, 2 wire panels allow any type of device (detectors, call points or sounders) to be connected in series on the same wire. However, alarm indication is still limited to only showing which zone the fire is in.
We’re often asked when to use smoke detectors and when to use heat detectors. Both types of detectors can detect a fire, but these products are actually designed to serve different needs:
Heat detectors are intended to minimize property damage by reacting to the change in temperature caused by a fire.
Smoke detectors are intended to protect people and property by generating an alarm earlier in the development of a fire. People need time to react, and every second is critical during an actual fire event.
When it comes to protecting people, it is critical to warn building occupants before smoke accumulates. Some types of fires “smolder,” or burn very slowly without flames. Burning slowly causes incomplete combustion, which in turn generates more smoke, carbon monoxide, and other poisonous gases. Smoldering fires also generate very little heat, making them difficult to detect with heat detectors. When people are harmed during a fire, the culprit is almost always smoke and poisonous gases like CO: not the heat or flames.
The main purpose of installing fixed fire-fighting equipment is to protect the property, especially in cases of large, open, fire more strongly endangered area.
According to the properties of the liquid and the extinguishing effect Bonpet the device is intended to extinguish fires classification A (solid) and B (flammable liquids) category.
Built-in current Bonpet extinguisher is designed as a built-zone fire extinguishing system.
DETAILS
Operation:
The principle of operation of the fixed fire-extinguishing system in the way of performance falls within the scope of spray fire extinguishing . It should be noted that the account of a piping nozzle and deploying such a system for spraying water , the only difference is the amount extinguis. Spraying water is primarily the task of the mediation of fire so the norms required by the spray of water a longer time. Spraying liquid fire Bonpet has basically the task extinguish the fire, due to its effectiveness, it is sufficient scatter significantly shorter duration of fluid (up to 20 seconds) and is not watering as needed in water . Given the exceptional ability to fire, therefore, in the container according to the calculation based on the surface of the quenching, there is a surprisingly small amount of extinguishing liquid Bonpet.
Equipment:
Built-in fire extinguisher consists of elements of mechanical and electrical equipment and is one of the low-pressure systems with operating pressures up to 5 bar fire, which means that for a system of pipelines using pipe and pipe fittings with low test pressure of 7.5 bar (water lines ).
Planning:
Design of fixed fire-fighting equipment is based on a view and plans of premises with technological equipment.Produces project documentation is subject to the applicable lawyers in the field of fire protection systems. The basis for developing the project is to determine the number of zones on the location of the fire equipment or materials on the premises. Based on the definition of the zones enforced calculate the volume of liquid fire Bonpet. The maximum calculated the quantity of extinguishing fluid Bonpet one zone is the basis for the selection of the size of the reservoir fluid Bonpet fire. With the amount of extinguishing liquid in the tank and the tank capacity is conditional on the size of the module, in the presence of all components to the tank.
* To embrace new technologies and methods. * To give unsurpassed products and services to the clients. * To constantly look for improvement and changes.